Partial-thickness scleral tethering suture for optimum fixation and centration of transscleral-sutured intraocular lens-capsule complex
نویسندگان
چکیده
منابع مشابه
Visual acuity after trans-scleral sutured posterior chamber intraocular lens.
OBJECTIVE To determine the changes in visual acuity in patients undergoing Trans-Scleral Sutured Posterior Chamber Intra-Ocular Lens (TSSPCIOL) implantation at a tertiary care hospital in Karachi, Pakistan. STUDY DESIGN Case series. PLACE AND DURATION OF STUDY LRBT Tertiary Eye Hospital, Karachi, from January 2006 to December 2010. METHODOLOGY Records of all patients undergoing implantati...
متن کاملSurgical technique for suture fixation of an acrylic intraocular lens in the absence of capsule support.
We present a technique for suture fixation of an intraocular lens (IOL) in the absence of capsule support. This technique is useful for the treatment of aphakia and the management of IOL complications or cataract surgery when all capsule support is lost.
متن کاملScleral Fixation of Intraocular Lens with Ab Interno Technique.
INTRODUCTION Implantation of scleral fixation intraocular lens for the surgical management of aphakia cases without capsular support is a safe procedure. METHODS Prospective study was carried out at Lumbini Eye Institute, Bhairahawa. A total of 32 patients underwent scleral fixation intraocular lens implantation within a period of two years from February 2014 to February 2016. RESULTS The a...
متن کاملScleral Fixation of Intraocular Lens Implants in Rural Medical College
Forty two patients (50 Eyes) with SFIOLs were considered for the study. 10/0 Polypropylene (Prolene) suture was used for transscleral fixation of the lens heptics. The transscleral suture passage was performed by simple Ab externo technique was done for all patients with 26 gauge hallow syringe neddle. Anterior vitrectomy was done in all cases. The follow up was ranged from minimum of 6 to 18 m...
متن کاملScleral fixation of a one-piece toric intraocular lens.
PURPOSE To describe a novel technique for toric intraocular lens (IOL) repositioning and fixation in the absence of adequate capsular support. METHODS Case report and literature review. RESULTS Two cases are presented with scleral fixation of a one-piece toric IOL (SN6AT series; Alcon Laboratories, Inc., Fort Worth, TX). In both cases, toric IOLs initially placed within the capsular bag bec...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Cataract & Refractive Surgery
سال: 2019
ISSN: 0886-3350
DOI: 10.1016/j.jcrs.2019.09.015