Partial Discharge Monitoring Method in Switchgear with Bushing High-Voltage Sensor

نویسندگان

چکیده

10 kV and 35 switchgear are the key equipment in power grid, safety of their insulation is related to stability entire grid. But accuracy traditional partial discharge detection method difficult meet requirements new SF6 insulated switchgear. This work analyzes feasibility using high-voltage sensor bushing detect discharge, analysis shows that synchronous signal can be obtained from sensor. Detection experiments were carried out three typical models, with both HFCT a The measurement results show effectively obtain PRPD plot similar HFCT. It also found adjusting sampling resistance change range

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Partial Discharge Detection of High Voltage Switchgear Using a Ultra High Frequency Sensor

Copyright 2013 KIEEME. All rights reserved. This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited. pISSN: 1229-7607 eISSN: 2092-7592 DOI: http://dx...

متن کامل

New Concept of High-voltage Switchgear On-line Monitoring System

A new concept of a high-voltage switchgear on-line monitoring system (BMS Bay Monitoring System) is described. Main features and benefits of BMS are simple ethernet-based communication which means simple LAN connectivity with other systems in a switchgear, reliable data collection, reliable controller operation, reliable power supply, quick access to data and a quick and simple retrieval of sto...

متن کامل

Partial Discharge in High Voltage Insulating Materials

High voltage transmission has been chosen in electric power system due to its capability to transfer a large amount of electric power. Several key equipments such as generator, transformer, GIS, cable and insulator play important role in determining the reliability of the power system. The high voltage equipments in general contain gas, liquid or solid insulation. Defects and a particular condi...

متن کامل

Partial Discharge Monitoring on Metal-Enclosed Switchgear with Distributed Non-Contact Sensors

Metal-enclosed switchgear, which are widely used in the distribution of electrical energy, play an important role in power distribution networks. Their safe operation is directly related to the reliability of power system as well as the power quality on the consumer side. Partial discharge detection is an effective way to identify potential faults and can be utilized for insulation diagnosis of...

متن کامل

Partial Discharge Pattern Recognition of Medium-Voltage Switchgear Based on Association Rules Mining

In the paper, a new partial discharge pattern recognition approach based on association rules mining is developed. Some statistical parameters are extracted from the sampled transient earth voltage data and classic Apriori algorithm is employed to mine the association rules between those parameters and the corresponding fault types. Moreover, using other experimental data obtained in the labora...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of physics

سال: 2022

ISSN: ['0022-3700', '1747-3721', '0368-3508', '1747-3713']