Partial Discharge Measurements in a High Voltage Gas Insulated Transmission Line Insulated with CO2
نویسندگان
چکیده
منابع مشابه
Disturbance Elimination for Partial Discharge Detection in the Spacer of Gas-Insulated Switchgears
With the increasing demand for precise condition monitoring and diagnosis of gas-insulated switchgears (GISs), it has become a challenge to improve the detection sensitivity of partial discharge (PD) induced in the GIS spacer. This paper deals with the elimination of the capacitive component from the phase-resolved partial discharge (PRPD) signal generated in GIS spacers based on discrete wavel...
متن کاملUHF Signal Processing and Pattern Recognition of Partial Discharge in Gas-Insulated Switchgear Using Chromatic Methodology
The ultra-high frequency (UHF) method is widely used in insulation condition assessment. However, UHF signal processing algorithms are complicated and the size of the result is large, which hinders extracting features and recognizing partial discharge (PD) patterns. This article investigated the chromatic methodology that is novel in PD detection. The principle of chromatic methodologies in col...
متن کاملStatus Review on Gas Insulated Switchgear Partial Discharge Diagnostic Technique for Preventive Maintenance
Gas insulated switchgear (GIS) plays a vital role in high voltage transmission of electrical energy due to its advantages of high reliability and performance, compact in dimensions and outstanding compatibility with the environment. It uses sulphur hexafluoride gas as its insulant and coolant because of its high dielectric strength and excellent arc quenching ability. Gas insulated switchgear i...
متن کاملDetection in Spacer of Gas-Insulated Switchgears
With the increasing demand for precise condition monitoring and diagnosis of 11 gas-insulated switchgears (GIS), it has become a challenge to improve the detection sensitivity of 12 partial discharge (PD) induced in the GIS spacer. This paper deals with the elimination of the 13 capacitive component from the phase resolved partial discharge (PRPD) signal generated in GIS 14 spacer based on the ...
متن کاملNew 550-kV Gas-insulated Switchgear
OVERVIEW: Hitachi has developed smaller and more reliable gas-insulated switchgear (GIS) in response to demands for lower costs and stable power supplies. Reliability of this GIS was improved and the enclosure diameter was reduced in order to minimize the installation space by using new analysis techniques and rationalization in insulation design and in temperature rise criteria. Furthermore, t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Energies
سال: 2020
ISSN: 1996-1073
DOI: 10.3390/en13112891