Partial discharge measurement and analysis in PPIs
نویسندگان
چکیده
منابع مشابه
the stady and analysis of rice agroclimatology in lenjan
the west of esfahan province, iran, is one of the most important agricultural areas throughout the country due to the climate variability and life-giving water of zayanderood river. rice is one of the major and economic crops in this area. the most important climatic elements in agricultural activities which should be considered include temperature, relative humidity, precipitation and wind. so...
15 صفحه اولComparison and Analysis of On-line Partial Discharge Measurement Methods for Gas Insulation Substation
In this paper, we compare and analyze the signals of acoustic emission (AE) sensor, high-frequency current transformer (HF-CT) and capacitive coupled (CC) sensor inspection methods when they are used to detect the partial discharge (PD) in gas isolation substations (GIS). The PD location feasibility of the AE method is also studied. In general, the leakage currents are measured by using the HF-...
متن کاملA Transformer Partial Discharge Measurement System Based on Fluorescent Fiber
Based on the physical phenomena of optical effects produced by the partial discharge (PD) and on the characteristics of fluorescent fiber sensing of weak fluorescent signals, a PD measurement system using a fluorescent fiber sensor was designed. The main parameters of the sensing system were calculated, an experimental testing platform for PD simulation in the lab was established, and PD signal...
متن کاملA Review of Online Partial Discharge Measurement of Large Generators
Online partial discharge (PD) measurements have long been used as an effective means to assess the condition of the stator windings of large generators. An increase in the use of PD online measurement systems during the last decade is evident. Improvements in the detection capabilities are partly the reason for the increased popularity. Another reason has been the development of digital signal ...
متن کاملCam Correlation Analysis Using Acoustic Discharge Measurement
The low head hydro power plant in Wettingen, Switzerland, is in operation since 1933 and no effective cam optimization has been carried out up to now. The goal of the measuring campaign was to provide data enabling an economic study for a retrofit and upgrade project of the plant and the measurement of the efficiency improvement of turbines after refurbishment. The contribution discusses cam te...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IET Power Electronics
سال: 2019
ISSN: 1755-4543,1755-4543
DOI: 10.1049/iet-pel.2018.5404