Partial Discharge Detection in Solid Dielectrics

Partial Discharge (PD) measurement and characterization provide vital information on insulation condition, different aspects of insulation ageing useful for equipment integrity verification and diagnosis. The work demonstrates standard test methods which employs capture of PD parameters with the aid of discharge detector. This paper investigates on the voltage amplitude at which PD of a specifi...

متن کامل

Partial Discharge in High Voltage Insulating Materials

High voltage transmission has been chosen in electric power system due to its capability to transfer a large amount of electric power. Several key equipments such as generator, transformer, GIS, cable and insulator play important role in determining the reliability of the power system. The high voltage equipments in general contain gas, liquid or solid insulation. Defects and a particular condi...

متن کامل

Estimation of HVDC Partial Discharge Incident Occurrences

Similar to AC system, the insulation system of DC system also gets affected. The HVDC station is a challenging environment for measurement of partial discharge level due to very high interference levels caused from the switching of thyristor-controlled converters. There is also significant interference from external air-corona due to high electric stress at the surface of conductors and hardwar...

متن کامل

Partial discharge database: its benefits and limitations on assessment of stator insulation deterioration

PD test data on various generators and motors has been collected over the last 15 years using on-line partial discharge analyzers. A large PD test database has been established. The database provides an overall view of PD activity on rotating machines. Statistical analysis of the database provides a study of PD distribution with variations of a number of the parameters. This paper presents stat...

متن کامل

Evaluating the Improvement of Partial Discharge Localization Accuracy Using Frequency Response Assurance Criterion

Partial Discharge (PD) is the most important source of insulation degradation in power transformers. In order to prevent catastrophic failures in transformers, PDs need to be located as soon as possible so that maintenance measures can be taken in time. Due to the structural complexity of windings, locating the PD source inside a transformer winding is not a simple task. In this paper, the effi...

متن کامل