Parity detection and entanglement with a Mach-Zehnder interferometer
نویسندگان
چکیده
منابع مشابه
Mach–Zehnder–Fano interferometer
We introduce a concept of the Mach–Zehnder–Fano interferometer by inserting a cavity exhibiting Fano resonance into a conventional interferometer. By employing the scattering-matrix approach, we demonstrate that the transmission becomes sensitive to a position of the cavity such that an asymmetric structure exhibits a series of narrow resonances with almost perfect reflection. We discuss how to...
متن کاملFactoring and Fourier transformation with a Mach-Zehnder interferometer
The scheme of Clauser and Dowling (Phys. Rev. A 53, 4587 (1996)) for factoring N by means of an N -slit interference experiment is translated into an experiment with a single Mach-Zehnder interferometer. With dispersive phase shifters the ratio of coherence length to wavelength limits the numbers that can be factored. A conservative estimate permits N ≈ 10. It is furthermore shown, that sine an...
متن کاملMach-Zehnder interferometer and the teleporter
We suggest a self-testing teleportation configuration for photon qubits based on a Mach-Zehnder interferometer. That is, Bob can tell how well the input state has been teleported without knowing what that input state was. One could imagine building a ‘‘locked’’ teleporter based on this configuration. The analysis is performed for continuous variable teleportation but the arrangement could be ap...
متن کاملAsymmetric Mach–Zehnder Interferometer Based Biosensors for Aflatoxin M1 Detection
In this work, we present a study of Aflatoxin M1 detection by photonic biosensors based on Si₃N₄ Asymmetric Mach-Zehnder Interferometer (aMZI) functionalized with antibodies fragments (Fab'). We measured a best volumetric sensitivity of 10⁴ rad/RIU, leading to a Limit of Detection below 5 × 10(-7) RIU. On sensors functionalized with Fab', we performed specific and non-specific sensing measureme...
متن کاملHighly stable polarization independent Mach-Zehnder interferometer.
We experimentally demonstrate optical Mach-Zehnder interferometer utilizing displaced Sagnac configuration to enhance its phase stability. The interferometer with footprint of 27×40 cm offers individually accessible paths and shows phase deviation less than 0.4° during a 250 s long measurement. The phase drift, evaluated by means of Allan deviation, stays below 3° or 7 nm for 1.5 h without any ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Physical Review B
سال: 2010
ISSN: 1098-0121,1550-235X
DOI: 10.1103/physrevb.82.155303