Parameter Analysis for Design of Concrete-Steel Hybrid Extradosed Bridge
نویسندگان
چکیده
منابع مشابه
Seismic Design of Concrete-Filled Circular Steel Bridge Piers
The adequacy of the existing design provisions for concrete-filled steel pipes subjected to axial forces and flexure is reviewed by comparing the strengths predicted by the CAN/CSA-S16.1-M94, AISC LRFD 1994, and the Eurocode 4 1994 codes and standards against experimental data from a number of investigators. New proposed design equations are then developed, in a format compatible with North Ame...
متن کاملAnalysis and Design of Steel-Concrete Composite Frame Systems
The lack of clear guidance regarding the value of elastic flexural rigidity (EI) that should be used in the analysis of steel-concrete composite columns is a significant unresolved issue that hinders the design of frame systems that include these members. The common approach of utilizing the rigidity of either the steel or the concrete only tends to be overly conservative. Other approaches that...
متن کاملNon - linear finite - element analysis of punching capacities of steel – concrete bridge deck slabs
j1 Yu Zheng MEng, PhD Associate Professor, Department of Civil Engineering, Dongguan University of Technology, Dongguan, PR China j2 Des Robinson PhD, MRAeS Senior Lecturer, School of Planning, Architecture and Civil Engineering, Queen’s University of Belfast, Belfast, UK j3 Su Taylor PhD, MICE Reader in Structural Engineering, School of Planning, Architecture and Civil Engineering, Queen’s Uni...
متن کاملNon-linear Analysis of Multi-hazard Performance of Cylindrical Concrete Filled Steel Tubes Bridge Piers
Advanced finite element techniques are used to investigate the multi-hazard (earthquake and blast) performance of Concrete-Filled Steel Tubes (CFSTs) and Concrete Filled Double Skinned Tubes (CFDSTs) for bridge engineering applications. Specimens of both sections are analyzed using the finite element package LS-DYNA under similar seismic and blast loading. First, behavior of CFSTs recorded in s...
متن کاملDynamic Analysis of Multihazard-Resistant Bridge Piers Having Concrete-Filled Steel Tube under Blast Loading
Research was conducted to analytically investigate the blast-response and behavior of multihazard-resistant bridge piers having circular-shaped, concrete-filled steel tube (CFST) columns. Two different analysis methods, namely a single-degree-of-freedom (SDOF) dynamic analysis and a fiber-based dynamic analysis, were used for this purpose and calibrated with the maximum residual deformations ob...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the Korea institute for structural maintenance and inspection
سال: 2011
ISSN: 2234-6937
DOI: 10.11112/jksmi.2011.15.6.100