Page mode reading with simulated scotomas: Oculo-motor patterns

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Page mode reading with simulated scotomas: Oculo-motor patterns

This study investigated the relationship between reading speed and oculo-motor parameters when normally sighted observers had to read single sentences with an artificial macular scotoma. Using multiple regression analysis, our main result shows that two significant predictors, number of saccades per sentence followed by average fixation duration, account for 94% of reading speed variance: readi...

متن کامل

Page mode reading with simulated scotomas: A modest effect of interline spacing on reading speed

Crowding is thought to be one potent limiting factor of reading in peripheral vision. While several studies investigated how crowding between horizontally adjacent letters or words can influence eccentric reading, little attention has been paid to the influence of vertically adjacent lines of text. The goal of this study was to examine the dependence of page mode reading performance (speed and ...

متن کامل

Erratum to “Page mode reading with simulated scotomas: A modest effect of interline spacing on reading speed” [Vision Research 47 (2007) 3447–3459]

In the author line, the names of the authors appear incorrectly, with the surname first. The correct author line appears above.

متن کامل

Reading with simulated scotomas: attending to the right is better than attending to the left

Persons with central field loss must learn to read using eccentric retina. To do this, most adopt a preferred retinal locus (PRL), which substitutes for the fovea. Patients who have central field loss due to age-related macular degeneration (AMD), most often adopt PRL adjacent to and to the left of their scotoma in visual field space. It has been hypothesized that this arrangement of PRL and sc...

متن کامل

Reading with a Simulated 60-Channel Implant

First generation retinal prostheses containing 50-60 electrodes are currently in clinical trials. The purpose of this study was to evaluate the theoretical upper limit (best possible) reading performance attainable with a state-of-the-art 60-channel retinal implant and to find the optimum viewing conditions for the task. Four normal volunteers performed full-page text reading tasks with a low-r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Vision Research

سال: 2008

ISSN: 0042-6989

DOI: 10.1016/j.visres.2008.06.005