Cardiac Pacemaker Battery Discharge After External Electrical Cardioversion for Broad QRS Complex Tachycardia
External electrical cardioversion or defibrillation may be necessary in patients with implanted cardiac pacemaker (PM) or implantable cardioverter defibrillator (ICD). Sudden discharge of high electrical energy employed in direct current (DC) transthoracic countershock may damage the PM/ICD system resulting in a series of possible device malfunctions. For this reason, when defibrillation or car...
متن کاملExternal electrical cardioversion of persistent atrial fibrillation in a patient with a Micra™ Transcatheter Pacing System
We report a case of a 85-year old woman with a preexisting Transcatheter Pacing System (TPS) (Micra™ VR, Fa. Medtronic, Inc., Minneapolis, MN, USA) undergoing several external electrical cardioversions (CV) for symptomatic persistent atrial fibrillation (persAF). Due to bradycardia in the setting of atrial fibrillation a right apical TPS implantation was performed earlier. Four weeks prior to p...
متن کاملMalfunction of the extracorporeal circulation system: case report.
BACKGROUND AND OBJECTIVES The introduction of extracorporeal circulation in clinical practice was decisive for the development of modern cardiovascular surgery. Addition of new procedures and equipment, however, brings inherent risks and complications. The objective of this report is to describe a malfunction of the oxygenation system and emphasize the importance of the interaction among the me...
متن کاملTriboelectric simulation of pacemaker malfunction.
We report the occurrence of a triboelectric phenomenon (static electricity) that mimicked malfunction of a contemporary pacemaker by creating an electrocardiograpic artifact virtually identical to the pacemaker stimuli. The diagnosis was established by observing a subtle overshoot of the questionable deflection that was absent from pacemaker stimuli.
متن کاملMuscle potentials simulating pacemaker malfunction.
Interference spikes were noted on the electrocardiogram of a patient with an implanted demand pacemaker. Runaway malfunction was suspected and the generator replaced. Subsequent investigation showec that the interference originated from fasciculation in the left leg caused by underlying neuromuscular disease. Skeletal muscle potentials can produce an electrocardiographic appearance closely rese...