[P232] Deformable image registration for CT-images of the thorax region
نویسندگان
چکیده
منابع مشابه
Validation of three deformable image registration algorithms for the thorax
Deformable image registration (DIR) has been proposed for lung ventilation calculation using 4D CT. Spatial accuracy of DIR can be evaluated using expert landmark correspondences. Additionally, image differences between the deformed and the target images give a degree of accuracy of DIR algorithms for the same image modality registration. DIR of the normal end-expiration (50%), end-inspiration ...
متن کاملA Study on Robustness of Various Deformable Image Registration Algorithms on Image Reconstruction Using 4DCT Thoracic Images
Background: Medical image interpolation is recently introduced as a helpful tool to obtain further information via initial available images taken by tomography systems. To do this, deformable image registration algorithms are mainly utilized to perform image interpolation using tomography images.Materials and Methods: In this work, 4DCT thoracic images of five real patients provided by DI...
متن کاملEvaluation of deformable image registration in HDR gynecological brachytherapy
Introduction: In brachytherapy, as in external radiotherapy, image-guidance plays an important role. For GYN treatments it is standard to acquire at least CT images and preferably MR images prior to each treatment and to calculate the dose of the day on each set of images. Then, the dose to the target and to the organs at risk (OAR) is calculated with worst case scenario from I...
متن کاملDeformable image registration of CT images for automatic contour propagation in radiation therapy.
Radiotherapy treatment plan may be replanned due the changes of tumors and organs at risk (OARs) during the treatment. Deformable image registration (DIR) based Computed Tomography (CT) contour propagation in the routine clinical setting is expected to reduce time needed for necessary manual tumors and OARs delineations and increase the efficiency of replanning. In this study, a DIR method was ...
متن کاملCT and PET Image Registration: Application to Thorax Area
Accurate attenuation correction of emission data is mandatory for quantitative analysis of PET images. One of the main concerns in CT-based attenuation correction (CTAC) of PET data in multimodality PET/CT imaging is misalignment occurred due to respiratory artifact between PET and CT images. In this paper a combined method which is simple and fast is proposed for registration of PET and CT dat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Physica Medica
سال: 2018
ISSN: 1120-1797
DOI: 10.1016/j.ejmp.2018.06.518