P0411 / #1109: IS TRACHEAL TUBE CUFF ASSOCIATED WITH POST EXTUBATION STRIDOR IN PEDIATRIC SUBJECTS?
نویسندگان
چکیده
منابع مشابه
Post-extubation stridor in Down's syndrome.
Laryngeal oedema, giving rise to stridor, is a recognized although rare complication following extubation of the trachea in children. It was our clinical impression that children with Down's syndrome, in particular, had a tendency to develop obstruction of the airway following operation. In Down's syndrome there are many abnormalities which affect the face and skull: those affect' ing the airwa...
متن کاملPost extubation stridor the call for objectivity.
In this issue of Indian Pediatrics, Sinha, et al.(1) have reported the results of a single center randomized controlled trial evaluating aerosolized L-epinephrine vs budesonide for the treatment of post-extubation stridor. While the benefits of intravenous corticosteroids on postextubation stridor are still unclear(2), the authors propose inhaled steroids may provide similar action to intraveno...
متن کاملCuff leak volume as a clinical predictor for identifying post-extubation stridor.
BACKGROUND Post-extubation stridor occurs after translaryngeal intubation results to re-intubation in a number of patients. OBJECTIVE To determine the cut-off value of the cuff leak volume test among Thai patients as a predictor for post-extubation stridor MATERIAL AND METHOD Demographic data and cuff leak volume were collected from patients who had been intubated with planned extubation. C...
متن کاملIntra-individual variation of the cuff-leak test as a predictor of post-extubation stridor.
BACKGROUND This was an evaluation of intra-individual variation of the cuff-leak test (ΔCLT) immediately post-intubation and pre-extubation, as a predictor of post-extubation stridor. METHODS Prospective, clinical investigation in the ICU of a non-university hospital. CLTs were performed immediately after intubation (T0) and before extubation (T1) to evaluate the differences in cuff leak (ΔCL...
متن کاملInspiratory stridor after tracheal intubation with a MicroCuff® tracheal tube in three young infants.
748 March 2013 U ncuffed tracheal tubes (TTs) have been the standard for tracheal intubation in infants and children for decades until the recent introduction of the Microcuff (Kimberley-clark, Roswell, GA) cuffed TT. evidence suggests that the incidence of perioperative airway events after use of these new TTs is small,1,2 although the evidence for their safe use in neonates and young infants ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Pediatric Critical Care Medicine
سال: 2021
ISSN: 1529-7535
DOI: 10.1097/01.pcc.0000739984.05204.d8