Oxygen inhalation—induced transcutaneous PO2 changes as a predictor of amputation level
نویسندگان
چکیده
منابع مشابه
Evaluation of the first day transcutaneous bilirubin (TcB) level as a predictor of hyperbilirubinemia in healthy term neonates
Background: The readmission rate for neonatal jaundice has been increased in recent years. This has been attributed to shorter length of postpartum hospital stays without comprehensive follow-up. The purpose of this study was to determine the diagnostic value of pre-discharge transcutaneous bilirubin (TcB) levels for prediction of subsequent hyperbilirubinemia in healthy term neonates. Metho...
متن کاملTranscutaneous Oxygen Tension as a Potential Predictor of Cardiovascular Events in Type 2 Diabetes
OBJECTIVE Transcutaneous oxygen tension (TcPO2) measures tissue perfusion and is important in the management of peripheral artery disease (PAD). Ankle brachial index (ABI) is used for the diagnosis of PAD and represents a predictor of major adverse cardiovascular events (MACE), even if in diabetes its diagnostic and predictive value seems to be reduced. No study has evaluated TcPO2 as a predict...
متن کاملevaluation of the first day transcutaneous bilirubin (tcb) level as a predictor of hyperbilirubinemia in healthy term neonates
background: the readmission rate for neonatal jaundice has been increased in recent years. this has been attributed to shorter length of postpartum hospital stays without comprehensive follow-up. the purpose of this study was to determine the diagnostic value of pre-discharge transcutaneous bilirubin (tcb) levels for prediction of subsequent hyperbilirubinemia in healthy term neonates. methods:...
متن کاملThe effect of adjuvant oxygen therapy on transcutaneous pO2 and healing in the below-knee amputee.
The effects on tissue oxygenation of postoperative adjuvant oxygen have been studied in a group of 20 patients undergoing below-knee (BK) amputation for vascular disease. Ten patients received no therapy, the remainder receiving 28% oxygen for 48 hours following surgery. The results showed that the transcutaneous pO2 in the amputation flaps fell significantly by some 20 mmHg (p less than 0.01) ...
متن کاملTranscutaneous pO2 imaging during tourniquet-induced forearm ischemia using planar optical oxygen sensors.
BACKGROUND Oxygen-dependent quenching of luminescence using transparent planar sensor foils was shown to overcome the limitations of the polarographic electrode technique in an animal model. This method was then transferred to a clinical setting to measure the transcutaneous pO(2) (p(tc)O(2)). METHODS In six healthy subjects, a cuff on the upper arm was occluded up to 20 mmHg above systolic p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Vascular Surgery
سال: 1985
ISSN: 0741-5214
DOI: 10.1016/0741-5214(85)90192-2