OVERVOLTAGE PROTECTION OF PV MICROINSTALLATIONS – REGULATORY REQUIREMENTS AND SIMULATION MODEL

نویسندگان

چکیده

In low-voltage power networks with a large share of distributed energy sources, the phenomenon overvoltage is increasingly observed. Although it may be desirable to raise voltage value downstream network, in some cases upper allowable limit exceeded. The method eliminating rises commonly used Polish system installation protections, disconnecting source from grid. Such action reduces profitability prosumer installations, discouraging future potential investors. It turns out, however, that this not only disadvantage such solution. Sudden and uncoordinated disconnections reconnections more sources cause abrupt changes negatively affect conditions network. aim paper present operating algorithms standard relay inverters photovoltaic microinstallations. These – described standards national regulations were tested typical inverter public implemented created simulation model relay. tests will for further work demonstrate need coordinate operation protections or replace them other measures improve grid high sources.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Requirements for Efficient Overvoltage Protection of Electronic Devices in Low-voltage Power Systems

Original scientific paper The increasing sensitivity of electronic devices widely used in low-voltage AC systems requires an appropriate protection against voltage and current surges. Protection of the equipment against the prospective surges is based on application of surge protection devices (SPDs). Most common situation, especially in residential buildings, is application of only one SPD at ...

متن کامل

Overvoltage protection and voltage stabilization for Motion Control terminals

This application example describes how Motion Control applications with the output stages for servo, DC and stepper motors by Beckhoff are optimized by the utilization of buffer capacitors. The buffer capacitor terminals EL9570 for EtherCAT and KL9570 for K-Bus stabilize the voltage supply by absorbing the fed back energy and dumping the energy that the buffer capacitor cannot protect against i...

متن کامل

Coordination of Overvoltage Protection in Low-Voltage Residential Systems

This paper was presented as a summary tutorial aimed at the French-speaking Canadian community to solicit their comments on the development of the IEEE Std 587 Guide. The paper has been translated into English by the author to make the English-speaking community aware of that paper, which served at that time as one output for the release of the extensive test results that were reported in the 3...

متن کامل

Transient overvoltage protection: The implications of new techniques

The paper presents a comparison of the performance of voltage-switching devices and voltage-limiting devices for late seventies-vintage SPDs as marketed and installed in service panels in the USA and in Europe. Artifacts in the response of a typical oscilloscope to a nearby gap sparkover, and the effect of lead dress inside the panels and outdoor installation are described. Predictably, the per...

متن کامل

the innovation of a statistical model to estimate dependable rainfall (dr) and develop it for determination and classification of drought and wet years of iran

آب حاصل از بارش منبع تأمین نیازهای بی شمار جانداران به ویژه انسان است و هرگونه کاهش در کم و کیف آن مستقیماً حیات موجودات زنده را تحت تأثیر منفی قرار می دهد. نوسان سال به سال بارش از ویژگی های اساسی و بسیار مهم بارش های سالانه ایران محسوب می شود که آثار زیان بار آن در تمام عرصه های اقتصادی، اجتماعی و حتی سیاسی- امنیتی به نحوی منعکس می شود. چون میزان آب ناشی از بارش یکی از مولفه های اصلی برنامه ...

15 صفحه اول

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie ?rodowiska

سال: 2021

ISSN: ['2083-0157', '2391-6761']

DOI: https://doi.org/10.35784/iapgos.2659