Outcomes of Stemmed versus Un-Stemmed Varus-Valgus Constrained Components in Primary Total Knee Arthroplasty

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Outcomes of Varus Valgus Constrained Versus Rotating-Hinge Implants in Total Knee Arthroplasty.

The stability of a total knee arthroplasty is determined by the ability of the prosthesis components in concert with supportive bone and soft tissue structures to sufficiently resist deforming forces transmitted across the knee joint. Constrained prostheses are used in unstable knees due to their ability to resist varus and valgus transformative forces across the knee. Constraint requires inher...

متن کامل

Stemmed revision arthroplasty for aseptic loosening of total knee replacement.

Fifty-three failed knee replacements were revised using minimally constrained implants with smooth uncemented intramedullary stems and metal-backed tibial components. Polymethylmethacrylate was used only to replace lost bone near the surface of the implant. Excluding four knees which had serious postoperative complications, 91% had successful relief of pain, 84% had over 90 degrees of movement ...

متن کامل

2- to 9-year outcome of stemmed total knee arthroplasty

BACKGROUND AND PURPOSE There is an increase in demand for primary and revision total knee joint procedures. We studied implant survival and functional outcome of patients operated with a constrained condylar knee (CCK) or a rotating hinge implant (RH) as a primary or a revision total knee arthoplasty (TKA). PATIENTS AND METHODS We evaluated clinically and radiographically 65 surgical procedur...

متن کامل

All-polyethylene versus metal-backed and stemmed tibial components in cemented total knee arthroplasty. A prospective, randomised RSA study.

We studied the quality of fixation of the tibial component using radiostereometric analysis (RSA) in 40 patients who had undergone a cemented Freeman-Samuelson total knee arthroplasty. They were prospectively randomised to either a stemmed metal-backed (MB) or non-stemmed all-polyethylene (AP) tibial component. The articulating geometry of the implants was identical, as was the operative techni...

متن کامل

Severe varus and valgus deformities treated by total knee arthroplasty.

We report a prospective case-controlled study which compared the outcome of knee replacement in seriously deformed and slightly deformed knees. There were 51 knees with varus or valgus deformity greater than 20 degrees matched for age, gender, disease, type of prosthesis and time of operation with a control group in which the alignment of the leg was within 5 degrees of normal. The clinical out...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Orthopedic Research and Reviews

سال: 2021

ISSN: 1179-1462

DOI: 10.2147/orr.s290015