Outcomes of Ahmed glaucoma valve implantation in advanced primary congenital glaucoma with previous surgical failure

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Outcomes of Ahmed glaucoma valve implantation in advanced primary congenital glaucoma with previous surgical failure

PURPOSE The purpose of this study was to evaluate the intermediate surgical results of Ahmed glaucoma valve (AGV) implantation in patients less than 7 years of age, with advanced primary congenital glaucoma who have failed previous surgeries. PATIENTS AND METHODS Consecutive patients with advanced primary congenital glaucoma that failed previous operations and had undergone subsequent AGV imp...

متن کامل

Outcomes of Ahmed glaucoma valve implantation in children with primary congenital glaucoma.

OBJECTIVES To evaluate the long-term efficacy of intraocular pressure reduction and complications of Ahmed glaucoma valve (AGV) implantation in children with primary congenital glaucoma. METHODS The medical records of patients with primary congenital glaucoma who underwent AGV implantation with a minimum follow-up of 6 months were reviewed. The primary outcome measure was cumulative probabili...

متن کامل

Surgical Results of Trabeculectomy and Ahmed Valve Implantation Following a Previous Failed Trabeculectomy in Primary Congenital Glaucoma Patients

PURPOSE To compare the surgical results of trabeculectomy and Ahmed glaucoma valve implantation after a previous failed trabeculectomy. METHODS A retrospective comparative case series review was performed on 31 eye surgeries in 20 patients with primary congenital glaucoma who underwent trabeculectomy or Ahmed glaucoma valve implantation after a previous failed trabeculectomy with mitomycin C....

متن کامل

Surgical Technique: Pars Plana Ahmed Glaucoma Valve Implantation

The pars plana model of the Ahmed Glaucoma Valve (AGV) is inserted into the vitreous cavity through a sclerostomy, and has a specially designed clip anchors that it in place and avoids tube kinking. The tube deliver aqueous from within the eye to the episcleral plate covered by Tenon’s capsule and conjunctiva, which stimulates fibrovascular encapsulation around the plate. This article elucidate...

متن کامل

Clinical findings following Ahmed Glaucoma Valve™ implantation in pediatric glaucoma

PURPOSE To describe clinical findings after Ahmed valve drainage implantation in children. DESIGN All records in one practice were reviewed to identify and describe clinical findings in all children who had undergone Ahmed Glaucoma Valve S2 model insertion for uncontrolled primary or secondary glaucoma. RESULTS A total of 6 patients were identified, ranging in age from 2-15 years. Mean foll...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Clinical Ophthalmology

سال: 2015

ISSN: 1177-5483

DOI: 10.2147/opth.s83820