Outcome of posterior chamber phakic intraocular lens procedure to correct myopia

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Outcome of posterior chamber phakic intraocular lens procedure to correct myopia.

PURPOSE To assess the safety and efficacy of the implantable contact lens (ICL™) to treat myopia. DESIGN Clinical, retrospective, single center, non-randomized case series. PARTICIPANTS Sixty-nine eyes of 46 patients with myopia ranging from -3.00 to 25.00 D were included in this study. INTERVENTION Implantation of the ICL™. MAIN OUTCOME MEASURES Uncorrected Visual Acuity (UCVA), refrac...

متن کامل

Posterior chamber phakic intraocular lens to correct myopia: long-term follow-up.

PURPOSE To evaluate the long-term safety and efficacy of a refractive phakic intraocular lens (pIOL) (PRL) to correct moderate to high myopia. SETTING Department of Ophthalmology, University Medicine Charité Berlin, Berlin, Germany. DESIGN Retrospective cohort study. METHODS Uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, intraocular pressure, endothelial cel...

متن کامل

Posterior chamber phakic intraocular lens implantation for high myopia.

OBJECTIVE To evaluate the efficacy, safety and stability of posterior chamber phakic intraocular lens (PIOLs) implantation for the correction of high myopia. METHODS Thirty-nine eyes of twenty patients with high myopia (between -11.75 and -25.75 diopters) had a posterior chamber PIOL (Staar ICL) implanted. During 6 - 48 months' follow-up, visual acuity, refraction, intraocular pressure (IOP),...

متن کامل

Posterior chamber collagen copolymer phakic intraocular lenses to correct myopia: five-year follow-up.

PURPOSE To evaluate the long-term safety and efficacy of posterior chamber collagen copolymer phakic intraocular lens (pIOL) implantation to correct myopia. SETTING Fernández-Vega Ophthalmological Institute, Oviedo, Spain. DESIGN Cohort study. METHODS Uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, pIOL vault, endothelial cell loss, and adverse events were ev...

متن کامل

Posterior chamber collagen copolymer phakic intraocular lens with a central hole for moderate-to-high myopia

The purpose of this article is to evaluate the clinical outcomes of a posterior chamber phakic intraocular lens (pIOL) (Visian Implantable Collamer Lens V4c) for the correction of moderate to high myopia in Chinese eyes.The article is designed as a retrospective case series.This study included the first consecutive eyes that had implantation of a new pIOL design with a central hole, at our depa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Saudi Journal of Ophthalmology

سال: 2013

ISSN: 1319-4534

DOI: 10.1016/j.sjopt.2013.06.009