Volar locking plate osteosynthesis for distal radial fractures.
PURPOSE To review the one-year outcome after volar locking plate fixation for distal radial fractures. METHODS Records of 22 men and 40 women aged 17 to 86 (mean, 52.5) years who underwent volar locking plate fixation for distal radial fractures were reviewed. According to the Fernandez classification, the distal radial fractures were classified as type 1 (n=20), type 2 (n=24), type 3 (n=6), ...
متن کاملTreatment of unstable distal radius fractures with the volar locking plate
BACKGROUND Open reduction and internal fixation using an interlocking plate system has gained popularity for the treatment of dorsally displaced distal radius fractures. PURPOSE To evaluate the functional and radiological results of treating unstable distal radius fractures with the volar locking plate. PATIENTS AND METHODS A retrospective review was conducted of patients from one instituti...
متن کاملVolar plate fixation of distal radius fractures.
Volar fixed angle fixation may be considered as the beginning of a new era in restoring wrist function to patients with dorsally displaced distal radius fractures even in the face of comminuted or osteopenic bone. A thorough understanding of the anatomy of the wrist is a prerequisite when volarly approaching dorsally displaced distal radius fractures. The demonstration of the device theoretical...
متن کاملsurgical treatment of unstable distal radius fractures with a volar variable-angle locking plate: clinical and radiological outcomes
conclusions the use of variable-angle locking plates in treating unstable distal end radius fractures is associated with excellent to good functional outcomes with minimal complications. objectives this study aimed to evaluate the functional and radiological outcomes in unstable distal end radius fractures treated with variable-angle locking plates. patients and methods we reviewed 23 unstable ...
متن کاملFunctional Results of Unstable (Type 2) Distal Clavicle Fractures Treated with Superior Anterior Locking Plate
Background: The treatment of distal clavicle fracture is always a challenge, as it is mostly unstable and has higherrate of delayed union, malunion, non-union and associated acromioclavicular arthritis. So the management of thesefractures remains controversial. The purpose of this study is to evaluate the functional results of Type 2 distal endclavicle fractures treated with superior anterior l...