Optimum Voxel Volume for Maximizing Contrast-to-Noise Ratio in BOLD Functional MRI

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimum Voxel Volume for Maximizing Contrast-to-Noise Ratio in BOLD Functional MRI

Recent studies suggest that physiological noise, which determines the SNR of the fMRI time course at commonly used spatial resolutions, is largely spatially coherent. It is theoretically shown that the ratio of such a spatially coherent physiological to thermal noise determines the optimum voxel volume for maximizing BOLD CNR, relatively independent of the size of activation.

متن کامل

Signal-to-noise ratio in MRI.

in RF receiving coil design. However, modern is proportional to 0 , so that their population imaging techniques often demand very high speed difference is larger at high values of 0 . Since the and spatial resolution, so that the highest possible ratio of the energy difference to thermal energy is SNR is still required to avoid poor image quality. very small, the population difference increases...

متن کامل

On the Definition of Signal-To-Noise Ratio and Contrast-To-Noise Ratio for fMRI Data

Signal-to-noise ratio, the ratio between signal and noise, is a quantity that has been well established for MRI data but is still subject of ongoing debate and confusion when it comes to fMRI data. fMRI data are characterised by small activation fluctuations in a background of noise. Depending on how the signal of interest and the noise are identified, signal-to-noise ratio for fMRI data is rep...

متن کامل

A Likelihood Ratio Test for Functional MRI Data Analysis to Account for Colored Noise

Functional magnetic resonance (fMRI) data are often corrupted with colored noise. To account for this type of noise, many prewhitening and pre-coloring strategies have been proposed to process the fMRI time series prior to statistical inference. In this paper, a generalized likelihood ratio test for brain activation detection is proposed in which the temporal correlation structure of the noise ...

متن کامل

Ultimate intrinsic signal-to-noise ratio in MRI.

A method to calculate the ultimate intrinsic signal-to-noise ratio (SNR) in a magnetic resonance experiment for a point inside an arbitrarily shaped object is presented. The ultimate intrinsic SNR is determined by body noise. A solution is obtained by optimizing the electromagnetic field to minimize total power deposition while maintaining a constant right-hand circularly polarized component of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: The Open Magnetic Resonance Journal

سال: 2008

ISSN: 1874-7698

DOI: 10.2174/1874769800801010054