Optimum under-frequency load shedding with comparison of two load models for distribution system

نویسندگان

چکیده

The distribution system connects customers to the rest of electrical grid. network suffers from rising power losses and low frequency, which are greater than transmission voltage problems. One solutions for these problems furnished by under-frequency load shedding based on optimal selection loads using a suitable optimization algorithm. Because its simple design inexpensive cost, radial (RDS) was chosen. Two models (constant model ZIP model) implemented with comparisons between them. A Gravitational binary search algorithm is used purpose accurate results, made demonstrate efficiency proposed method. BGSA useful in order reduce space minimum be shed location. IEEE 33-bus employed check validity suggested attitudes. Direct Backward Forward Sweep Method (DBFSM) show total each node as it represents flow method RDS. results ability provided methodologies find best solution large loss reduction better profile

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Improved Under-Frequency Load Shedding Scheme in Distribution Networks with Distributed Generation

When a distribution network consisting of Distributed Generations (DGs) is disconnected from upstream network, the system may be exposed to severe power imbalance. In order to prevent the damage of power plants, frequency relays operate and remove DGs from the network. In contrast to traditional methods, the main objective in new methods is to keep DG units in service in the islanded distributi...

متن کامل

an improved under-frequency load shedding scheme in distribution networks with distributed generation

when a distribution network consisting of distributed generations (dgs) is disconnected from upstream network, the system may be exposed to severe power imbalance. in order to prevent the damage of power plants, frequency relays operate and remove dgs from the network. in contrast to traditional methods, the main objective in new methods is to keep dg units in service in the islanded distributi...

متن کامل

A Fuzzy Based Under-Frequency Load Shedding Scheme for Islanded Distribution Network Connected with DG

The frequency of power system is very sensitive to load changing when operating in islanded mode. This may causes overloading or loss of generation cases. Under-Frequency Load Shedding (UFLS) Scheme is commonly applied to stabilize the frequency during these cases. Conventional UFLS scheme operates successfully in interconnected grid system and may not work well when applied to DG based system ...

متن کامل

Swarm Evolutionary Programming for Under-Frequency Load Shedding

In this paper, Swarm Evolutionary Programming (SEP) method incorporating modified System Frequency Response (SFR) model is proposed to solve the optimal Under-frequency Load Shedding (UFLS) scheme design problem. The objective function of this problem is to minimize transient frequency and steady-state frequency deviation from nominal and total quantum of load shedding. The constrained optimiza...

متن کامل

Under Frequency Load shedding Algorithm in Smart Islanded Networks Using Loads Frequency Index

This paper presents an optimal method of frequency load shedding (UFLS) based on the rate of change of frequency of load (ROCOFL) in islanded distribution networks (DN). The proposed method minimizes the average amount of penalties paid by the independent operator of the network by utilizing the relevant cost function. The function of islanded distribution network occurs after an error in the s...