منابع مشابه
Tesla Polarimeters
We describe a study of high-energy Compton beam polarimeters for the future ee linear collider machine TESLA. A segment of the beam delivery system has been identified, which is aligned with the ee collision axis and which has a suitable configuration for high-quality beam polarization measurements. The laser envisaged for the polarimeter is similar to an existing facility at DESY. It delivers ...
متن کاملParametric Investigation of Optimum Thermal Insulation Thickness for External Walls
Numerous studies have estimated the optimum thickness of thermal insulation materials used in building walls for different climate conditions. The economic parameters (inflation rate, discount rate, lifetime and energy costs), the heating/cooling loads of the building, the wall structure and the properties of the insulation material all affect the optimum insulation thickness. This study focuse...
متن کاملDetermination of Optimum Insulation Thickness for Building Walls in Iran Using Life Cycle Cost Analysis
Air-Conditioning (AC) systems are responsible for a considerable portion of the energy consumption in buildings located in high cooling load requiring regions of Iran. In addition, the heat flow through the buildingschr('39') external walls plays a major role in cooling load estimations for the countrychr('39')s hot regions. Therefore, application of insulation materials in external walls has g...
متن کاملOptimizing imaging polarimeters constructed with imperfect optics.
Imaging polarimeters are often designed and optimized by assuming that the polarization properties of the optics are nearly ideal. For example, we often assume that the linear polarizers have infinite extinction ratios. It is also usually assumed that the retarding elements have retardances that do not vary either spatially or with the angle of incidence. We consider the case where the polariza...
متن کاملAn improved microgrid arrangement for integrated imaging polarimeters
For almost 20 years, microgrid polarimetric imaging systems have been built using a 2 × 2 repeating pattern of polarization analyzers. In this paper, we show that superior spatial resolution is achieved over this 2 × 2 case when the analyzers are arranged in a 2 × 4 repeating pattern. This unconventional result, in which a more distributed sampling pattern results in finer spatial resolution, i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
سال: 2004
ISSN: 0168-9002
DOI: 10.1016/j.nima.2004.02.045