OPTIMUM RELIEF FORCE OF OIL DAMPERS IN MULTI-STORY BUILDINGS
نویسندگان
چکیده
منابع مشابه
Sound insulation in multi-story timber buildings
During on an extensive investigation of a multi-story timber building with light-frame construction, several stages of the building process and their impact on sound transmission were observed. The sound insulation properties of the building components were measured before and while the buildings were occupied. Furthermore, interviews with the occupants were conducted. This procedure made it po...
متن کاملStructural Magnetic Induction Dampers in Buildings
This thesis discusses the feasibility of structural magnetic induction dampers for dampening mechanical vibrations in buildings subjected to strong dynamic excitations. The concept of energy harvesting in various fields of engineering is first examined. Then it is applied to the design of magnetic induction dampers in buildings. Various implementations of these dampers are proposed and the rela...
متن کاملA COMPARATIVE STUDY OF OPTIMUM AND IRANIAN SEISMIC DESIGN FORCE DISTRIBUTIONS FOR STEEL MOMENT RESISTING BUILDINGS
In this study, constant-ductility optimization algorithm under a family of earthquake ground motions is utilized to achieve uniform damage distribution over the height of steel moment resisting frames (SMRFs). SMRF structures with stiffness-degrading hysteric behavior are modeled as single-bay generic frame in which the plastic hinge is confined only at the beam ends and the bottom of the first...
متن کاملSeismic Design of Multi-story Buildings with Metallic Structural Fuses
Seismic design relies on inelastic deformations through hysteretic behavior. However, this translates into damage on structural elements, permanent system deformations following an earthquake, and possibly high cost for repairs. An alternative design approach is to concentrate damage on disposable and easy to repair structural elements (i.e., “structural fuses”), while the main structure is des...
متن کاملSemi-active Base isolation System for Buildings using MR Dampers
Due to limitations on the use of passive base isolation systems which show poor performance in near field seismic excitations or active systems which require high external power, as stand alone control devices for a range of seismic excitations, a hybrid control system that mitigates the limitations of either passive or active control systems is preferred. The present study examines the use of ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Structural and Construction Engineering (Transactions of AIJ)
سال: 2012
ISSN: 1340-4202,1881-8153
DOI: 10.3130/aijs.77.1237