OPTIMUM DESIGN FOR STRUCTURAL SYSTEM WITH MAXWELL TYPE VISCOUS DAMPER BASED ON STOCHASTICALLY EQUIVALENT DAMPING FACTOR

نویسندگان

چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Equivalent Damping Ratios of Structures with Supplemental Viscous Dampers

The current design formulas such as those provided by FEMA273/274 for building structures with supplemental viscous dampers were derived based on the shear building assumption. However, for medium-rise to high-rise buildings that deform in a combined form of shear and bending when subjected to seismic loading, the design using existing formulas may result into an actual damping ratio much lower...

متن کامل

Advanced damper with high stiffness and high hysteresis damping based on negative structural stiffness

0020-7683/$ see front matter 2013 Elsevier Ltd. A http://dx.doi.org/10.1016/j.ijsolstr.2013.03.018 ⇑ Corresponding authors. Tel.: +1 608 346 7275 (L. Don E-mail addresses: [email protected] (L. (R. Lakes). High structural damping combined with high stiffness is achieved by negative stiffness elements. Negative incremental structural stiffness occurs when a column with flat ends is subjecte...

متن کامل

OPTIMUM LAYOUT OF NONLINEAR FLUID VISCOUS DAMPER FOR IMPROVEMENT THE RESPONSES OF TALL BUILDINGS

The utilization of passive energy dissipation systems has been created a revolution in the structural engineering industry due to their advantages. Fluid Viscous Damper (FVD) is one of these control systems. It has been used in many different industries, such as the army, aerospace, bridge, and building structures. One of the essential questions about this system is how it can combine with the ...

متن کامل

Viscous vs. Structural Damping in Modal Analysis

It is shown that among the various damping mechanisms that are generally encountered in a mechanical structure, only the “viscous component” actually accounts for energy loss. The remaining portion of the damping force is due to non-linearities, which do not dissipate energy. Consequently, a linear model of a vibratory mechanical system involves only viscous damping, although the damping factor...

متن کامل

a new type-ii fuzzy logic based controller for non-linear dynamical systems with application to 3-psp parallel robot

abstract type-ii fuzzy logic has shown its superiority over traditional fuzzy logic when dealing with uncertainty. type-ii fuzzy logic controllers are however newer and more promising approaches that have been recently applied to various fields due to their significant contribution especially when the noise (as an important instance of uncertainty) emerges. during the design of type- i fuz...

15 صفحه اول

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Structural and Construction Engineering (Transactions of AIJ)

سال: 2011

ISSN: 1881-8153,1340-4202

DOI: 10.3130/aijs.76.1649