Optimum Automatic Frequency Ratio Control System by HVDC Transmission and its Test Results in Actual Field
نویسندگان
چکیده
منابع مشابه
Distributed Control of HVDC Transmission Grids
Priority access of renewable resources such as offshore wind recommended by European energy directives, new market models and trading the electric energy among countries lead to new requirements on the operation and expansion of transmission grids. Since AC grid expansions are limited by legislative issues and long distance transmission capacity, there is a considerable attention drawn to appli...
متن کاملDecreasing the Commutation Failure Frequency in HVDC Transmission Systems
In this paper we show how a fairly large proportion of those commutation failures that are due to single-phased short circuits to earth can be avoided. In a control circuit based on a digital signal processor (DSP) it is possible, with instantaneous results, to switch from a normal control strategy with equidistant firing pulses to a strategy that takes into consideration the potentially danger...
متن کاملReliability Improvement Strategies for HVDC Transmission System
This paper analyses reliability data of HVDC systems of Southern China Power Grid. The weak links of HVDC systems’ operational reliability are DC control and protection, valve hall and valve cooling system and transmission lines. Some improvement measures and HVDC system reliability technology are proposed in this paper.
متن کاملModern Control and Protection System for Hvdc
For High Voltage Direct Current (HVDC) applications, the control and protection system plays an essential role in the overall performance of the transmission system. The control and protection system adopted by ABB Power Systems uses the latest technology from the fields of electronics and microprocessors. The main objective of this paper is to describe the experience from using the MACHTM (Mod...
متن کاملHVDC Transmission with STATCOM
Most of the HVDC power converters with thyristor valves are assembled in a converter Bridge of Six pulse configuration. Converter transformers with one DC side winding as an ungrounded star connection and the other a delta configuration. Comparative studies of the two systems of HVDC CIGRE model without STATCOM and with STATCOM were performed. In these case, the consideration was the converter ...