Optimizing parametrial aperture design utilizing HDR brachytherapy isodose distribution
نویسندگان
چکیده
منابع مشابه
Optimizing parametrial aperture design utilizing HDR brachytherapy isodose distribution
Treatment of cervical cancer includes combination of external beam radiation therapy (EBRT) and brachytherapy (BRT). Traditionally, coronal images displaying dose distribution from a ring and tandem (R&T) implant aid in construction of parametrial boost fields. This research aimed to evaluate a method of shaping parametrial fields utilizing contours created from the high-dose-rate (HDR) BRT dos...
متن کاملEP-1230: Optimizing HDR brachytherapy dose distributions with respect to dosimetric indices and homogenei
Figure shows the absolute change in the Dmean for the anal sphincter (left y-axis) and relative change in the V64Gy for the rectal wall (right y-axis) expressed as a function of the relative increase in the homogeneity index HI of the dose distribution in the PTV. Conclusions: By increasing the inhomogeneity of the targeted dose to the PTV in prostate RT plans the dose delivered to the rectal w...
متن کاملPractical considerations for prostate HDR brachytherapy.
PURPOSE A process for prostate high-dose-rate (HDR) brachytherapy was developed and implemented successfully in the community hospital setting. The practical aspects of the program are reviewed and may serve as a foundation for clinics interested in offering this clinical service. METHODS AND MATERIALS A generic needle distribution geometry was established to accommodate target volumes of var...
متن کاملIPIP: A new approach to inverse planning for HDR brachytherapy by directly optimizing dosimetric indices.
PURPOSE Many planning methods for high dose rate (HDR) brachytherapy require an iterative approach. A set of computational parameters are hypothesized that will give a dose plan that meets dosimetric criteria. A dose plan is computed using these parameters, and if any dosimetric criteria are not met, the process is iterated until a suitable dose plan is found. In this way, the dose distribution...
متن کاملEvaluation of deformable image registration in HDR gynecological brachytherapy
Introduction: In brachytherapy, as in external radiotherapy, image-guidance plays an important role. For GYN treatments it is standard to acquire at least CT images and preferably MR images prior to each treatment and to calculate the dose of the day on each set of images. Then, the dose to the target and to the organs at risk (OAR) is calculated with worst case scenario from I...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Contemporary Brachytherapy
سال: 2013
ISSN: 1689-832X
DOI: 10.5114/jcb.2013.34341