Optimizing Cu removal/recovery in a biosorption column
نویسندگان
چکیده
منابع مشابه
Behavior of the mass transfer zone in a biosorption column.
Modeling of the mass transfer zone behavior under variable conditions in a flow-through fixed-bed sorption column enabled the prediction of breakthrough curves for Cu2+ and Ca-preloaded Sargassum fluitans biomass. The mass transfer resistance, particle diffusion, and the axial dispersion were incorporated in the model. The dynamics of the mass transfer zone was described under variable sorption...
متن کاملDivalent Cu, Cd, and Pb Biosorption in Mixed Solvents
Dead dried Chlorella vulgaris was studied in terms of its performance in binding divalent copper, cadmium, and lead ions from their aqueous or 50% v/v methanol, ethanol, and acetone solutions. The percentage uptake of cadmium ions exhibited a general decrease with decrease in dielectric constant values, while that of copper and lead ions showed a general decrease with increase in donor numbers....
متن کاملColumn biosorption of lanthanum and europium by Sargassum.
Batch and column biosorption of La(3+) (lanthanum) and Eu(3+) (europium) was studied using protonated Sargassum polycystum biomass. The ion exchange sorption mechanism was confirmed by the proportional release of protons and by the total normality of the solution, which remained constant during the process. Equilibrium isotherms were determined for the binary systems, La/H and Eu/H for a total ...
متن کاملOptimal Operation of a Three-Product Dividing-Wall Column with Self-Optimizing Control Structure Design
This paper deals with optimal operation of a three-product Dividing-Wall Column (DWC). The main idea is to design a control structure, through a systematic procedure for plantwide control, with an objective to achieve desired product purities with the minimum use of energy. Exact local method is used to find the best controlled variables as single measurement or combination of measurements ...
متن کاملOptogalvanic isotope enrichment of Cu ions in Cu-Ne positive column discharges.
The isotopic enrichment of copper ions in a positive column Cu-Ne discharge using optogalvanic excitation is analyzed with a rate equation model. With excitation at 510.6 nm, the fraction of the ions belonging to the 63-amu isotope of copper is enriched relative to the neutral abundance. Enrichment as large as 10% is calculated when the initial abundance of the neutral isotope is small (<0.1) a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Water Research
سال: 1997
ISSN: 0043-1354
DOI: 10.1016/s0043-1354(97)00071-7