Optimized readout system for cooled optically stimulated luminescence
نویسندگان
چکیده
منابع مشابه
Optically stimulated luminescence in synthetic quartz
Optically stiniulated luminescence (OSL). has been studied in synthetic quartz crystals. which had previously been exposed to Jtor X-irradiations. The main emission hands appeared at 380 and -~440 nm. The excitation spectra of these emission bands were now measured and showed both a maximum at 330nm. This maximum coincides with an excitation maximum of the phototransferred thermoluminescence (P...
متن کاملOptically Stimulated Luminescence Dating (Instrument Design for Mars Applications)
Introduction: To examine the geological and climatic history on Mars, we investigate an instrument design for robotic, in-situ, Optically Stimulated Luminescence dating (OSL). In this paper, we discuss the basic concepts of OSL, its benefits, and how this technique can be utilized on Mars. Also presented are the vital electronics needed for an instrument design and some of their basic operation...
متن کاملMgO:Li,Ce,Sm as a high-sensitivity material for Optically Stimulated Luminescence dosimetry.
The goal of this work was to investigate the relevant dosimetric and luminescent properties of MgO:Li3%,Ce0.03%,Sm0.03%, a newly-developed, high sensitivity Optically Stimulated Luminescence (OSL) material of low effective atomic number (Zeff = 10.8) and potential interest for medical and personal dosimetry. We characterized the thermoluminescence (TL), OSL, radioluminescence (RL), and OSL emis...
متن کاملOptically stimulated luminescence (OSL) of carbon-doped aluminum oxide (Al2O3:C) for film dosimetry in radiotherapy.
INTRODUCTION AND PURPOSE Conventional x-ray films and radiochromic films have inherent challenges for high precision radiotherapy dosimetry. Here we have investigated basic characteristics of optically stimulated luminescence (OSL) of irradiated films containing carbon-doped aluminum oxide (Al2O3:C) for dosimetry in therapeutic photon and electron beams. MATERIALS AND METHODS The OSL films co...
متن کاملA methodology for on‐board CBCT imaging dose using optically stimulated luminescence detectors
Cone-beam computed tomography CBCT systems are used in radiation therapy for patient alignment and positioning. The CBCT imaging procedure for patient setup adds substantial radiation dose to patient's normal tissue. This study pre-sents a complete procedure for the CBCT dosimetry using the InLight optically-stimulated-luminescence (OSL) nanoDots. We report five dose parameters: the mean slice ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Radiation Effects and Defects in Solids
سال: 1991
ISSN: 1042-0150,1029-4953
DOI: 10.1080/10420159108224847