Optimized Energy Window Configuration for 201Tl Imaging
نویسندگان
چکیده
منابع مشابه
Optimized energy window configuration for 201Tl imaging.
UNLABELLED A poor signal-to-noise ratio attributable to a low injected dose of thallium and the presence of scattered photons are the major impediments in the use of thallium as an imaging agent. Thallium decays in a complicated way and emits photons in a wide range of energies (68-82 keV). To increase the ratios of primary photons to scatter photons (primary-to-scatter ratios) and possibly inc...
متن کاملEnergy window setting for optimum Tl-201 cardiac imaging [Persian]
Introduction: Poor sensitivity and poor signal to noise ratio because of low injected thallium dose and presence of scattered photons are the main problems in using thallium in scintigraphic imaging of the heart. Scattered photons are the main cause of degrading the contrast and resolution in SPECT imaging that result in error in quantification. Thallium decay is ve...
متن کاملenergy window setting for optimum tl-201 cardiac imaging [persian]
introduction: poor sensitivity and poor signal to noise ratio because of low injected thallium dose and presence of scattered photons are the main problems in using thallium in scintigraphic imaging of the heart. scattered photons are the main cause of degrading the contrast and resolution in spect imaging that result in error in quantification. thallium decay is very complicated and photons ar...
متن کاملMyocardial perfusion imaging with 201Tl.
The object of this review is to provide information about (201)Tl-thallous chloride in radionuclide myocardial perfusion imaging. This technique has experienced a recent resurgence because of the shortage of (99m)Tc. After reading this article, the technologist will be able to describe the properties and uptake mechanism of (201)Tl, the procedure for myocardial perfusion imaging with this agent...
متن کاملAppropriate energy window width for gamma camera [Persian]
Introduction: Scatter radiation is one of the major sources of error in nuclear medicine data processing. Different methods of scatter correction have been introduced in order to improve the quality of data. However the best method is to avoid recording of scatter photons in acquisition. The only difference between scattered and non-scattered photons is the energy. Pulse height analyzer i...