Optimized 3D ultrashort echo time pulmonary MRI

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimized 3D ultrashort echo time pulmonary MRI.

PURPOSE To optimize 3D radial ultrashort echo time MRI for high resolution whole-lung imaging. METHODS 3D radial ultrashort echo time was implemented on a 3T scanner to investigate the effects of: (1) limited field-of-view excitation, (2) variable density readouts, and (3) radial oversampling. Improvements in noise performance and spatial resolution were assessed through simulation and phanto...

متن کامل

Preliminary use of a double-echo pulse sequence with 3D ultrashort echo time in the MRI of bones and joints

The aim of the present study was to investigate the application of a double-echo pulse sequence with 3D ultrashort echo time (UTE) in the magnetic resonance imaging (MRI) of bones and joints. In total, 7 healthy volunteers and 1 volunteer with a suspected tear of the lateral meniscus of the left knee joint underwent MRI with a double-echo pulse sequence and 3D UTE. The imaging was performed on ...

متن کامل

MRI-based attenuation correction for PET/MRI using ultrashort echo time sequences.

UNLABELLED One of the challenges in PET/MRI is the derivation of an attenuation map to correct the PET image for attenuation. Different methods have been suggested for deriving the attenuation map from an MR image. Because the low signal intensity of cortical bone on images acquired with conventional MRI sequences makes it difficult to detect this tissue type, these methods rely on some sort of...

متن کامل

3D pulmonary perfusion MRI with radial ultra-short echo time and spatial-temporal constrained reconstruction

Figure 4. Quantitative evaluation of PBF (ml blood/100ml lung/min), PBV (ml blood/100ml lung) and MTT s in a 23 years old female patient with Factor V Leiden using PCB+ST reconstruction. 3D pulmonary perfusion MRI with radial ultra-short echo time and spatial-temporal constrained reconstruction Grzegorz Bauman, Kevin M Johnson, Laura C Bell, Julia V Velikina, Alexey A Samsonov, Scott K Nagle, a...

متن کامل

Optimized three-dimensional fast-spin-echo MRI.

Spin-echo-based acquisitions are the workhorse of clinical MRI because they provide a variety of useful image contrasts and are resistant to image artifacts from radio-frequency or static field inhomogeneity. Three-dimensional (3D) acquisitions provide datasets that can be retrospectively reformatted for viewing in freely selectable orientations, and are thus advantageous for evaluating the com...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Magnetic Resonance in Medicine

سال: 2012

ISSN: 0740-3194

DOI: 10.1002/mrm.24570