Optimization of the Plate Heat Exchanger Used for Milk Precooling
نویسندگان
چکیده
Abstract The article deals with the adjustment of flow rate milk and water by a plate heat exchanger, which is used for precooling milk. First, measurements parameters device in stable were carried out. Subsequently, exchanger was measured laboratory. Water at 35 °C instead Different ratios cooling cooled (instead milk) set. From values, changes temperature calculated depending on its constant ratio water. It found that range, there are values change maximal. This dependence applies to all selected ratios: (0.8, 0.9, 1.0, 1.1, 1.2.). results show same amount water, it possible achieve greater 0.7 1.6 °C, or reduction consumption. farm modified allow be changed. optimal set, verification performed. saving 4.8% confirmed.
منابع مشابه
Analysis of Gasketed-plate Heat Exchanger Performance Using Nanofluid
A heat exchanger using nanofluid needs to operate at optimum mass concentration level to get the maximum heat transfer performance. A numerical analysis is performed on the heat transfer and pressure drop of water-based γ-Al2O3 nanofluid gasketed-plate heat exchanger to specify its optimum conditions. Cold water will be heated by γ-Al2O3/water nanofluid. The results showed that optimal volume c...
متن کاملThermodynamic Optimization of Plate-fin Heat Exchanger Using Teaching-learning- Based Optimization (tlbo) Algorithm
This study explores the use of teaching-learning-based optimization (TLBO) algorithm for thermodynamic optimization of a plate-fin heat exchanger. Minimizing the total number of entropy generation units for specific heat duty requirement under given space restrictions is considered as objective function. Based on the applications heat exchanger length, fin frequency, numbers of fin layers, lanc...
متن کاملAnalysis of Heat Transfer Enhancement in Spiral Plate Heat Exchanger
In the present study, the heat transfer coefficients of benzene in a spiral plate heat exchanger are investigated. The test section consists of a Plate of width 0.3150 m, thickness 0.001 m and Mean hydraulic diameter of 0.01 m. The mass flow rate of water (Hot fluid) is varying from 0.5 kg sec to 0.8 kg sec and the mass flow rate of benzene (cold fluid) varies from 0.4 kg sec to 0.7 kg sec. Exp...
متن کاملPlate Heat Exchanger Optimization Using Different Approximation Assisted Multiobjective Optimization Techniques
This paper presents a comparison between different multiobjective optimization approaches that can be used to optimize the design of thermal equipment. Plate heat exchanger is taken as case study to apply different optimization techniques. The thermal-hydrodynamic characteristics of single phase turbulent flow in chevron-type plate heat exchangers with sinusoidal-shaped corrugations have been u...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Acta Technologica Agriculturae
سال: 2023
ISSN: ['1335-2555', '1338-5267']
DOI: https://doi.org/10.2478/ata-2023-0016