Optimization of Current Total Harmonic Distortion in Series-Connected Rectifiers
نویسندگان
چکیده
منابع مشابه
Total harmonic distortion reduction add-on unit for three-phase diode rectifiers
ELECT An active add-on option for 208 VLL/60 Hz passive three-phase rectifiers is presented. The active optional circuit is implemented as ‘centretapped’ full-bridge stage and guarantees low-harmonic input currents and unity power factor. The active unit is able to operate for a wide frequency range and therefore applicable for high(e.g. >100 kW) and low-power applications. Some basic considera...
متن کاملA Novel 36-pulse rectifier with low kVA rate to reduce harmonic input current distortion
The increase in the number of pulses in multipulse rectifiers leads to a reduction in harmonic current distortion. But this increase in the number of pulses leads to an increase in kVA, cost, and complexity of the multi-pulse rectifiers. As a result, in industrial applications, 12-pulse rectifiers are mainly used due to their lightweight, simple transformers, and low kVA rate, and low cost. The...
متن کاملQuantum rectifiers from harmonic mixing
– We investigate dissipative quantum transport in extended periodic systems that are subjected to electric harmonic mixing fields Ehm(t) = E1 cos(Ωt)+E2 cos(2Ωt+φ). Although such a drive possesses no net bias on average, the interplay of quantum dissipation and nonlinear response causes a finite directed current. We thus discover the paradigm of a dissipative quantum rectifier. The quantum curr...
متن کاملTotal Harmonic Distortion Analysis of Front End Current for Diode Rectifier with Sepic Pfc
Front end current distortion of rectifier converter leads to low power factor, high THD, distribution system losses, neutral harmonic currents, over rated power equipments in a power system. In addition, the presence of harmonics in line currents may lead current distortion, create additional heating and over voltage problem, loading and losses in the utility distribution systems. The aim of th...
متن کاملTotal Harmonic Distortion and Effects in Electrical Power Systems
Introduction The power quality of distribution systems has a drastic effect on power regulation and consumption. Johan Lundquist of the Chalmers University of Technology in Goteberg, Sweden put it best, stating “The phrase ‘power quality’ has been widely used during the last decade and includes all aspects of events in the system that deviates from normal operation.” This has been especially tr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Renewable Energy and Power Quality Journal
سال: 2010
ISSN: 2172-038X
DOI: 10.24084/repqj08.325