OPTIMIZATION OF CONSTRUCTION FOR UNDERGROUND LNG STORAGE TANK
نویسندگان
چکیده
منابع مشابه
CFD Modelling of an Underground Water Tank Heat Storage System
In this work, CFD is used to simulate the flow in an existing thermal labyrinth located at the basement of a hospital building. This labyrinth is an underground channel equipped with water tanks to increase the thermal mass and reduce the heating and cooling demand of the building. Thermal energy storage in the water tanks is a complex heat transfer phenomena involving turbulent forced convecti...
متن کاملAerobic biodegradation of methyl tert-butyl ether by aquifer bacteria from leaking underground storage tank sites.
The potential for aerobic methyl tert-butyl ether (MTBE) degradation was investigated with microcosms containing aquifer sediment and groundwater from four MTBE-contaminated sites characterized by oxygen-limited in situ conditions. MTBE depletion was observed for sediments from two sites (e.g., 4.5 mg/liter degraded in 15 days after a 4-day lag period), whereas no consumption of MTBE was observ...
متن کاملField note phytovolatilization of oxygenated gasoline-impacted groundwater at an underground storage tank site via conifers.
A stand of five conifers (Pinus sp.) bordering a gasoline service station was studied to estimate the methyl tert-butyl ether (MTBE) emission rate from gasoline-impacted groundwater. Groundwater was impacted with gasoline oxygenates MTBE and tert-butyl alcohol (TBA) at combined concentrations exceeding 200,000 microg/L. Condensate from trees was collected in sealed environmental chambers and an...
متن کاملStorage Tank Design
A calculus problem arising in the operation of a storage tank for a chemical processing plant is described. Constructing an appropriate gauge for the storage tank requires computing the volume of water residing inside a tilted cylindrical pipe. The following calculus problem arose in the engineering design of a storage tank facility, and is possibly more interesting and challenging for students...
متن کاملOptimization of Operating Procedure of LNG Storage Facilities Using Rigorous BOR Model
Abstract: In this study, in order to improve the efficiency and the safety of the LNG storage facilities, the rigorous hybrid dynamical model is proposed. This model is composed of continuous state dynamics which estimate the boil-off rate (BOR) based on understanding of the energy and mass transfer between the stratified cells of LNG storage tanks and discrete state dynamics which describe the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Doboku Gakkai Ronbunshuu F
سال: 2009
ISSN: 1880-6074
DOI: 10.2208/jscejf.65.434