This paper shows a method for the optimization of the design of a building integrated photovoltaic system minimizing costs over life-time, through the use of Radiance software, taking into account the constraints imposed by the architecture of the building and of the surroundings. It calculates the annual solar radiation in many spots of a surface (flat or complex) from a geometry defined by th...
متن کاملEnergy Saving Evaluation of the Ventilated BIPV Walls
This study integrates photovoltaic (PV) system, building structure, and heat flow mechanism to propose the notion of ventilated Building-Integrated Photovoltaic (BIPV) walls. The energy-saving potential of the ventilated BIPV walls was investigated via engineering considerations and computational fluid dynamics (CFD) simulations. The results show that the heat removal rate and indoor heat gain ...
متن کاملArchitectural design of an advanced naturally ventilated building form
Advanced stack-ventilated buildings have the potential to consume much less energy for space conditioning than typical mechanically ventilated or air-conditioned buildings. This paper describes how environmental design considerations in general, and ventilation considerations in particular, shape the architecture of advanced naturally ventilated (ANV) buildings. The attributes of simple and adv...
متن کاملVariability of Thermal Stratification in Naturally Ventilated
Building energy simulation programs often use standard thermal comfort indices and thresholds as boundary conditions. However, most of them focus on comfortable indoor hydrothermal levels, rather than spatial distributions. This paper investigates internal temperature vertical stratification in naturally ventilated residential buildings. To evaluate this effect, a field study was carried out in...
متن کاملOptimization of Sampling Positions for Measuring Ventilation Rates in Naturally Ventilated Buildings Using Tracer Gas
Finding out the optimal sampling positions for measurement of ventilation rates in a naturally ventilated building using tracer gas is a challenge. Affected by the wind and the opening status, the representative positions inside the building may change dynamically at any time. An optimization procedure using the Response Surface Methodology (RSM) was conducted. In this method, the concentration...