Optimising acquisition parameters for myocardial T2 mapping using T2-prep at 3T

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimising acquisition parameters for myocardial T2 mapping using T2-prep at 3T

Background T2 mapping using T2-prepared SSFP at 1.5T has been shown to be sensitive to oedema in acute myocardial infarction[1]. At 3T, other studies have addressed the problem of the T2 prep module’s sensitivity to the increased B1 inhomogeneity[2]. However, a second problem is that the lengthened T1 at 3T can reduce the contrast between normal and oedematous myocardium, as well as introducing...

متن کامل

Robust myocardial T2 and T2* mapping at 3T

PURPOSE Intramyocardial hemorrhage and area at risk are both prognostic markers in acute myocardial infarction (AMI). Myocardial T2 and T2 * mapping have been used to detect such tissue changes at 1.5T but these techniques are challenging at 3.0T due to additional susceptibility variation. We studied T2 and T2 * myocardial mapping techniques at 3.0T on a system employing B1 shimming and compare...

متن کامل

Self-navigated three-dimensional cardiac T2 mapping at 3T

Background Cardiac T2 mapping using a variable T2 preparation module (T2Prep) has recently gained attention for its ability to quantify the extent of edema (Giri, JCMR 2009). Due to time constraints, the T2 maps are commonly acquired as one or several two-dimensional slices, while the underlying pathology has a three-dimensional (3D) structure. The next logical step would therefore be to exploi...

متن کامل

Single-breathhold Myocardial T2 and T2* Quantification in Normal Volunteer Subjects at 3T

H. GUO, J. S. CHEUNG, D. KIM, P-L. KHONG, G. M. BRITTENHAM, AND E. X. WU LABORATORY OF BIOMEDICAL IMAGING AND SIGNAL PROCESSING, THE UNIVERSITY OF HONG KONG, HONG KONG, CHINA, PEOPLE'S REPUBLIC OF, DEPARTMENT OF ELECTRICAL AND ELECTRONIC ENGINEERING, THE UNIVERSITY OF HONG KONG, HONG KONG, CHINA, PEOPLE'S REPUBLIC OF, DEPARTMENT OF RADIOLOGY, NEW YORK UNIVERSITY SCHOOL OF MEDICINE, NEW YORK, UN...

متن کامل

Fast, whole-heart, free-breathing 3D T2 mapping at 3T with application to myocardial edema imaging

Background Cardiac MRI (CMR) T2 mapping is a proven method for myocardial edema detection. However, the current approach requires multiple breath-holds and can take nearly 10-15 minutes to complete. Faster acquisitions could potentially improve patient comfort and costeffectiveness of CMR exams. the objecttive of this study is to develop and test a free-breathing, three-dimensional, cardiac MR ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Cardiovascular Magnetic Resonance

سال: 2013

ISSN: 1532-429X

DOI: 10.1186/1532-429x-15-s1-w10