This paper presents a three-dimensional numerical and experimental geometric optimization study to maximize the total heat transfer rate between a bundle of finned tubes in a given volume and external flow, for staggered arrangements of circular and elliptic tubes. Experimental results were obtained for circular and elliptic configurations with twelve tubes, starting with an equilateral triangl...
متن کاملAnalysis of variance of nanofluid heat transfer data for forced convection in horizontal spirally coiled tubes
In the present study, an experimental study is carried out to investigate the effect of adding Al and Cu nanoparticles to the base fluid (water) on the heat transfer rate in a spirally coiled tube. The spirally coiled tube is fabricated from the straight copper tube with the inner and outer coil diameters of 100 and 420 mm, respectively. The experiments have been done for water and two types of...
متن کاملCharacteristics of forced convection heat transfer in vertical internally finned tube
This work presents a numerical investigation of a vertical internally finned tube subjected to forced convection heat transfer. The governing equations were solved numerically using the control volume technique. Nusselt number, Nu, and friction factor multiplied by Reynolds number, fRe, are influenced greatly by the height and number of the radial fins. The velocity and temperature distribution...
متن کاملDetermination of the Heat Transfer Coefficient Distribution on the Longitudinal Finned Tubes in Staggered Arrangement Using Inverse and Cfd Method
Abstract. This paper presents results of an experimental study on heat exchanger consisting of finned tube.The presented method for determining the local heat transfer coefficient on external tube surfaces is characterized by very high accuracy and can be applied to determine the spatial heat transfer distribution on objects with a complex shape. As a results of experimental and numerical inves...
متن کاملForced Convection Model Of Fan Plate-Finned Tube Type Heat Exchanger At Low Reynolds Numbers
The forced convection experiment of fan plate-finned tube heat exchangers which are mainly used in air conditioners and the forced convection model have been studied for which the heat transfer effect of this type exchangers has not been proposed by a model. All measurements were made when there is no refrigerant flow in the pipe at Reynolds's number of 580. According to the experiment results,...