OPTIMALISASI UNJUK KERJA COOLING TOWER DI PT. GEO DIPA ENERGI UNIT PATUHA

نویسندگان

چکیده

Cooling tower pada industri panas bumi digunakan untuk mendinginkan air pendingin kondensor turbin. Salah satu jenis cooling ini adalah induce draft counterflow dengan flow rate desain 9.259 ton/h. Proses pendinginan dilakukan menggunakan 5 buah cell temperatur masuk 41,6?C yang didinginkan hingga 20,2?C. Berdasarkan data commissioning tahun 2014, efektivitas sebesar 81,06% dan saat mengalami penurunan menjadi 71,21%. Sedangkan kondisi operasi bedasarkan perhitungan telah 9,85%. Bedasarkan permasalahan tersebut, divisi maintenance melakukan modifikasi pembersihan komponen tower. Hasil analisa dari diperoleh maksimal 82,70% kehilangan kalor 500.693.666,5 KJ/jam.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cooling Tower Energy & Operating Cost Analysis Software

The Cooling Tower Energy & Operating Cost Analysis Software is an in-house program developed by Tower Tech and is used to design and evaluate the performance and life-cycle costs associated with a cooling tower. This version can be used to estimate the cost to purchase and operate a Tower Tech cooling tower and a competitor’s tower. A number of assumptions about the details of the competitor’s ...

متن کامل

The Geo-Net-PT/Yahoo! GeoPlanet concordance

Background: Geo-Net-PT is a geospatial ontology representing the Portuguese territory and the relations between the several locations within it. Yahoo! GeoPlanet is a geospatial ontology that covers the whole world. To interlink the two ontologies and reduce the effects of repeated information, we propose an automatic alignment between their administrative parts, based on name similarity and ph...

متن کامل

Study of Degradation of Dry Cooling Tower Performance under Wind Conditions and Method for Tower Efficiency Enhancement (RESEARCH NOTE)

Wind affects adversely the cooling tower thermal performance. A field investigation was carried out to study the thermal performance of Heller cooling towers under wind conditions, involving measurement of wind velocity and its direction around the cooling tower, and obtaining water flow rates and temperatures at the cooling tower inlet and outlet. Results show that air suction at the tower top...

متن کامل

Snowfall observations from natural-draft cooling tower plumes.

During the winter of 1975-1976, snowfall from the plumes of large natural-draft cooling towers of power plants has been observed. Snow accumulations up to 2.5 centimeters have been found on the ground at extended distances from the cooling towers, and visibility has been restricted to less than 1600 meters in the tower plume near ground level.

متن کامل

Optimization of Water - Cooled Chiller – Cooling Tower Combinations

Water-cooled chiller systems have typically been designed around entering condenser water temperatures of 85°F with a Optimization of Water Cooled Chiller – Cooling Tower Combinations The warm water leaving the chilled water coils is pumped to the evaporator of the chiller, where the unwanted heat from the building is transferred by the latent heat of vaporization of the refrigerant. The compre...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Indonesian Journal of Energy and Mineral

سال: 2023

ISSN: ['2797-9911']

DOI: https://doi.org/10.53026/ijoem/2023/3.1/1035