Optimal Viscous Damper Placement for Elastic-Plastic MDOF Structures Under Critical Double Impulse
نویسندگان
چکیده
منابع مشابه
Critical Response of 2DOF Elastic–Plastic Building Structures under Double Impulse as Substitute of Near-Fault Ground Motion
The double impulse is introduced as a substitute of the fling-step near-fault ground motion and a critical elastic–plastic response of a two-degree-of-freedom (2DOF) building structure under the “critical double impulse” is evaluated. Since only the free-vibration appears under such double impulse, the energy balance approach plays an important and essential role in the derivation of the soluti...
متن کاملVISCOUS DAMPER PLACEMENT OPTIMIZATION IN CONCRETE STRUCTURES USING COLLIDING BODIES ALGORITHM AND STORY DAMAGE INDEX
Dampers can reduce structural response under dynamic loads. Since dampers are costly, the design of structures equipped with dampers should make their application economically justifiable. Among the effective cost reduction factors is optimal damper placement. Hence, this study intended to find the optimal viscous damper placement using efficient optimization methods. Taking into account the no...
متن کاملActive viscous damping system for control of MDOF structures
The development and applications of a supplemental viscous damping device with active capacity are described. The system of the dampers de ned as active viscous damping system (AVDS) is presented herein. Structural control principles de ned here as active control theory (ACT) are used to obtain the control forces at each time step during an excitation. Control of the damping forces is possible ...
متن کاملCritical Input and Response of Elastic–Plastic Structures Under Long-Duration Earthquake Ground Motions
The multiple impulse input is introduced as a substitute of the long-duration earthquake ground motion, mostly expressed in terms of harmonic waves, and a closed-form solution is derived of the elastic–plastic response of a single-degree-of-freedom structure under the “critical multiple impulse input.” Since only the free vibration appears under such multiple impulse input, the energy approach ...
متن کاملthe optimal tadas damper placement in moment resisting steel structures based on a cost-benefit analysis
in this paper, the optimal location and characteristics of tadas dampers in moment resisting steel structures, considering the application of minimum number of tadas dampers in a building as an objective function and the restriction for destruction of main members is studied. genetic algorithm in first generation randomly produces different chromosomes representing unique tadas dampers distribu...