Optimal Sizing of Capacitor Bank for Increasing Substation Capacity of Mamou

نویسندگان

چکیده

In order to increase the available power of electrical energy distribution station and improve voltage profile lines, use shunt capacitor banks is indicated. The main results obtained during this study are: a reduction in subscribed from 14913.978 kVA 14010.100 kVA, transformer load rate 99.4% 93.4%, reactive called 5481.729 kVAr 481.729 kVAr, an active transported by substation 8505.062 kW 8962.323 kW, drop 4.8% 3.9%, at secondary full 13950 14700 annual saving 339943.48 kWh energy, therefore fuel savings CO2 SO2 emissions due will be achieved. installation for optimization allowed current absorbed power: 14153.061 i.e. 903.876 kVA. It essential that players are convinced need install capacitors reduce or even eliminate their bill. This necessarily accompanied investment Electricité De Guinée setting up meters but also implementing pricing line with transfer network.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A MULTISTAGE EXPANSION PLANNING METHOD FOR OPTIMAL SUBSTATION PLACEMENT

Optimal distribution substation placement is one of the major components of optimal distribution system planning projects. In this paper optimal substation placement problem is solved using Imperialist Competitive Algorithm (ICA) as a new developed heuristic optimization algorithm. This procedure gives the optimal size, site and installation time of medium voltage substation, using their relate...

متن کامل

A fuzzy-based approach for optimal allocation and sizing of capacitor banks

This paper proposes a fuzzy set optimization approach for capacitor allocation in radial distribution system. In this approach, a membership function for voltage profile constraint has been used. Moreover, another membership function incorporating feeder section active power losses and total power losses constraints has been proposed. This membership function indirectly imposes thermal capabili...

متن کامل

Fuseless Capacitor Bank Protection

The use of fuseless capacitor banks requires subtle changes in the protection approach from the more traditional fused banks. This paper covers the aspects of protecting fuseless capacitor banks of various voltage classes. Comparison of fused versus fuseless capacitor bank protection is discussed, along with examples and insights from Minnesota Power’s experiences with fuseless capacitor banks.

متن کامل

study of cohesive devices in the textbook of english for the students of apsychology by rastegarpour

this study investigates the cohesive devices used in the textbook of english for the students of psychology. the research questions and hypotheses in the present study are based on what frequency and distribution of grammatical and lexical cohesive devices are. then, to answer the questions all grammatical and lexical cohesive devices in reading comprehension passages from 6 units of 21units th...

Capacitor Bank Designing for Power Factor Improvement

Various inductive loads used in all industries deals with the problem of power factor improvement. Capacitor bank connected in shunt helps in maintaining the power factor closer to unity. They improve the electrical supply quality and increase the efficiency of the system. Also the line losses are also reduced. Shunt capacitor banks are less costly and can be installed anywhere. This paper deal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: World Journal of Engineering and Technology

سال: 2023

ISSN: ['2331-4222', '2331-4249']

DOI: https://doi.org/10.4236/wjet.2023.112015