Optimal Size and Location for Corneal Rotational Autografts
نویسندگان
چکیده
منابع مشابه
Optimal size and location for corneal rotational autografts: a simplified mathematical model.
OBJECTIVE To calculate clinical guidelines for the optimal location and size of a rotational autokeratoplasty. METHODS The ideal graft size and trephine decentration for a rotational autograft were calculated based on scar location using geometric models. Mathematical variables were set to maximize postoperative visual acuity and for generalization of the geometric model. This model was used ...
متن کاملOptimal Earthmoving Fleet Size for Minimising Emissions and Cost
Traditionally, the earthmoving operations have been developed based on the minimum cost per production criterion. Nowadays, due to the negative impacts of the emissions on the environment, there is an increasing public awareness to reduce the emissions from the earthmoving operations. Different management strategies can be employed to reduce emissions, amongst other things, which can also resul...
متن کاملa benchmarking approach to optimal asset allocation for insurers and pension funds
uncertainty in the financial market will be driven by underlying brownian motions, while the assets are assumed to be general stochastic processes adapted to the filtration of the brownian motions. the goal of this study is to calculate the accumulated wealth in order to optimize the expected terminal value using a suitable utility function. this thesis introduced the lim-wong’s benchmark fun...
15 صفحه اولACL graft failure location differs between allografts and autografts
BACKGROUND Between 5 and 20% of patients undergoing ACL reconstruction fail and require revision. Animal studies have demonstrated slower incorporation of allograft tissue, which may affect the mechanism of graft failure. The purpose of this study is to determine the location of traumatic graft failure following ACL reconstruction and investigate differences in failure patterns between autograf...
متن کاملDelayed suprachoroidal haemorrhage following Boston Keratoprosthesis in two aniridic patients.
REFERENCES 1. Groden LR, Arentsen JJ. Ipsilateral rotating autokeratoplasty. Ann Ophthalmology 1983;15:899e901. 2. Jonas J, Rank R, Budde W. Autologous ipsilateral rotating penetrating keratoplasty. Am J Ophthalmol 2001;131:427e30. 3. Lee J, Winokur J, Hallak J, et al. Femtosecond dovetail penetrating keratoplasty: surgical technique and case report. Br J Ophthalmol 2009;93:861e3. 4. Holzer MP,...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Archives of Ophthalmology
سال: 2006
ISSN: 0003-9950
DOI: 10.1001/archopht.124.3.410