Optimal Placement of PMU with FACTS for Voltage Stability Analysis
نویسندگان
چکیده
منابع مشابه
Optimal PMU Placement Considering with HVDC Links and Their Voltage Stability Requirements
In wide area measurement systems, PMUs are the main component measuring real time synchronized data from different buses. Installation of PMUs at all buses is a primary way to provide full observability of the power network. However, it is not practical in real networks due to the relatively expensive cost of PMUs and other technical limitations. Optimal PMU Placement (OPP) is an optimization p...
متن کاملStrategic PMU placement for stability enhancement
This paper explored a novel method for strategic monitoring of a power system to schematically monitor power system variables that are sensitive to transients. The characteristics of a fully developed transient or power swing increase frequency slip rates, generator pole slips, rotor out-of-step etc. whose effects lead to loss of synchronism of coherent generators in a power system. When these ...
متن کاملObservability of power systems with optimal PMU placement
Phasor Measurement Units (PMUs) are measuring devices that, when placed in electrical networks, observe their state by providing information on the currents in their branches (transmission lines) and voltages in their buses. Compared to other devices, PMUs have the capability of observing other nodes besides the ones they are placed on. Due to a set of observability rules, depending on the plac...
متن کاملOptimal Multistage Scheduling of Pmu Placement for Power System Observability
The standards of power system monitoring, control and protection are elevated by Phasor Measurement Units (PMUs) as an auspicious tool. It is the purpose of this paper to determine the optimal number and locations of PMUs so as to make the system measurement model observable and also estimate the power system state. The proposed modelling approach which models PMU placement as an integer linear...
متن کاملAn optimal PMU placement technique for power system observability
0142-0615/$ see front matter 2012 Elsevier Ltd. A http://dx.doi.org/10.1016/j.ijepes.2012.03.011 ⇑ Corresponding author. E-mail address: [email protected] (B.K. Saha Roy Power system state estimation with exclusive utilization of synchronous phasor measurements demands that the system should be completely observable through PMUs only. To have minimum number of PMUs, the PMU placement issue in an...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: HELIX
سال: 2020
ISSN: 2277-3495,2319-5592
DOI: 10.29042/2020-10-2-203-210