Optimal imaging with adaptive mesh refinement in electrical impedance tomography
نویسندگان
چکیده
منابع مشابه
Optimal imaging with adaptive mesh refinement in electrical impedance tomography.
In non-linear electrical impedance tomography the goodness of fit of the trial images is assessed by the well-established statistical chi2 criterion applied to the measured and predicted datasets. Further selection from the range of images that fit the data is effected by imposing an explicit constraint on the form of the image, such as the minimization of the image gradients. In particular, th...
متن کاملAdaptive mesh refinement techniques for electrical impedance tomography.
Adaptive mesh refinement techniques can be applied to increase the efficiency of electrical impedance tomography reconstruction algorithms by reducing computational and storage cost as well as providing problem-dependent solution structures. A self-adaptive refinement algorithm based on an a posteriori error estimate has been developed and its results are shown in comparison with uniform mesh r...
متن کاملApplications of Electrical Impedance Tomography in Neurology
Introduction: Electrical impedance tomography (EIT) is a non-invasive technique utilized in various medical applications, including brain imaging and other neurological diseases. Recognizing the physiological and anatomical characteristics of organs based on their electrical properties is one of the main applications of EIT, as each variety of tissue structure has its own electrical characteris...
متن کاملDistributed tomography with adaptive mesh refinement in sensor networks
Existing seismic instrumentation systems do not yet have the capability to recover the physical dynamics with sufficient resolution in real time. Currently, seismologists use centralized tomography inversion algorithm for which the data is gathered either manually from each station or by using limited number of expensive broadband stations. This scheme can take months to generate tomography and...
متن کاملAn Automatic Neural-Networks Based Mesh Refinement Method for Electrical Impedance Tomography
In real life applications, inverse problems, such as the electrical impedance tomography problem, usually have a limited accuracy, and require huge computation resources to be solved correctly. In electrical impedance tomography, the goal is to obtain the electrical properties of different materials (typically living tissues) by applying an electrical current and measuring the resulting potenti...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Physiological Measurement
سال: 2002
ISSN: 0967-3334,1361-6579
DOI: 10.1088/0967-3334/23/1/311