Optimal Design of Multiple Tuned Liquid Column Dampers for Seismic Vibration Control of MDOF Structures
نویسندگان
چکیده
منابع مشابه
OPTIMIZED TUNED LIQUID COLUMN DAMPERS FOR EARTHQUAKE OSCILLATIONS OF HIGH-RISE STRUCTURES INCLUDING SOIL EFFECTS
This paper investigates the optimized parameters for the tuned liquid column dampers to decrease the earthquake vibrations of high-rise buildings. Considering soil effects, the soilstructure interaction (SSI) is involved in this model. The Tuned Liquid Column Damper (TLCD) is also utilized on the roof of the building. Since the TLCD is a nonlinear device, the time domain analysis based on nonli...
متن کاملdual-layer multiple tuned mass dampers for vibration control of structures
the performance of dual-layer multiple tuned mass dampers (dl-mtmd) with uniformly distributed natural frequencies is investigated. the dl-mtmd consists of one large tuned mass damper (l-tmd) and an arbitrary number of small tuned mass dampers (s-tmd). the primary structure is represented as a single degree-of-freedom system which corresponds to a specific vibration mode to be controlled in a r...
متن کاملreducing the seismic response of nonlinear hysteretic structures using optimal multiple tuned mass dampers
in this research, the effectiveness of multiple tuned mass dampers (mtmds) in mitigating the response of nonlinear hysteretic structures has been studied where the optimal parameters of mtmds have been determined based on minimization of maximum relative displacement (drift) of structure. for solving the optimization problem the genetic algorithm (ga) has been used successfully. for numerical a...
متن کاملPerformance of Tuned Liquid Dampers with Different Tank Geometries for Vibration Control of Structures
TLD is a tank filled with water and serves as a dynamic vibration absorber for passive control of structures. This paper addresses the comparisons of TLD performances corresponding to different tank geometries including rectangular and conical shapes. Due to the importance of water and tank weight as a load on top of a building, volume is considered to be a constant parameter in this study. Fir...
متن کاملearthquake vibration control of structures using tuned liquid dampers: experimental studies
earlier studies have shown conclusively that a tuned liquid damper (tld) is effective for controlling vibrations in structures subjected to narrow-banded wind excitations. a recent numerical study has shown that if the design parameters of a tld are properly set, this device could also be very effective for controlling structural vibration to broad-banded earthquake excitations. here the result...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Periodica Polytechnica Civil Engineering
سال: 2015
ISSN: 0553-6626,1587-3773
DOI: 10.3311/ppci.7645