Optimal Design of Corona Ring for 132 kV Insulator at High Voltage Transmission Lines Based on Optimisation Techniques
نویسندگان
چکیده
The installation of a corona ring on an insulator string transmission line is one the solutions to reduce electric field stress surrounding energised end string. However, installing with optimum design magnitude challenging task. Therefore, in this work, method achieve for 132 kV composite non-ceramic was proposed using two optimisation methods: Imperialist Competitive Algorithm (ICA) and Grey Wolf Optimisation (GWO). A geometry without modelled finite element analysis used obtain distribution model geometry. evaluated variation ring’s dimensions, i.e., diameter, tube diameter vertical position along From results achieved, comparison minimum shows that found be lower techniques compared by between 3.724% 3.827%. Hence, indicates capability effectiveness methods achieving
منابع مشابه
Effects of Disc Insulator Type and Corona Ring on Electric Field and Voltage Distribution over 230-kV Insulator String by Numerical Method
Insulator strings with several material and profiles are very common in overhead transmission lines. However, the electric field and voltage distribution of insulator string is uneven which may easily lead to corona, insulators’ surface deterioration and even flashover. So the calculation of the electric field and voltage distribution along them is a very important factor in the operation time....
متن کاملFault Locating in High Voltage Transmission Lines Based on Harmonic Components of One-end Voltage Using Random Forests
In this paper, an approach is proposed for accurate locating of single phase faults in transmission lines using voltage signals measured at one-end. In this method, harmonic components of the voltage signals are extracted through Discrete Fourier Transform (DFT) and are normalized by a transformation. The proposed fault locator, which is designed based on Random Forests (RF) algorithm, is train...
متن کاملA Three-Dimensional Analysis of Silicone Rubber Insulators Under Different Environmental Conditions Considering the Corona Rings Effect
Since the insulators of transmission lines are exposed to different environmental conditions, it is important task to study insulators performance under different conditions. In this paper, silicone rubber insulators performance under different environmental conditions including rainy, icy, salt and cement are proposed and exactly is studied. Electric fields (E-fields) and voltage distributions...
متن کاملConductor Corona Noise Prediction on High Voltage Ac Lines
The conductor corona noise of four local 400 kV AC transmission lines is measured and compared to predictions. The prediction software developed is based on the EPRI semi-analytical approach using excitation functions and the theory of natural modes. The nature and accuracy of the prediction software is discussed along with relevant corona noise metrology issues encountered.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Energies
سال: 2023
ISSN: ['1996-1073']
DOI: https://doi.org/10.3390/en16020778