Optimal C-arm angulation during transcatheter aortic valve replacement: Accuracy of a rotational C-arm computed tomography based three dimensional heart model
نویسندگان
چکیده
منابع مشابه
Optimal C-arm angulation during transcatheter aortic valve replacement: Accuracy of a rotational C-arm computed tomography based three dimensional heart model
AIM To investigate the accuracy of a rotational C-arm CT-based 3D heart model to predict an optimal C-arm configuration during transcatheter aortic valve replacement (TAVR). METHODS Rotational C-arm CT (RCT) under rapid ventricular pacing was performed in 57 consecutive patients with severe aortic stenosis as part of the pre-procedural cardiac catheterization. With prototype software each RCT...
متن کاملTranscatheter Aortic Valve Replacement: A Review Article
Transcatheter aortic valve replacement (TAVR) is a novel therapeutic intervention for the replacement of severely stenotic aortic valves in high-risk patients for standard surgical procedures. Since the initial PARTNER trial results, use of TAVR has been on the rise each year. New delivery methods and different valves have been developed and modified in order to promote the minimally invasive p...
متن کاملThree-dimensional echocardiography vs. computed tomography for transcatheter aortic valve replacement sizing.
AIMS The accuracy of transcatheter aortic valve replacement (TAVR) sizing using three-dimensional transoesophageal echocardiography (3D-TEE) compared with the gold-standard multi-slice computed tomography (MSCT) remains unclear. We compare aortic annulus measurements assessed using these two imaging modalities. METHODS AND RESULTS We performed a single-centre prospective cohort study, includi...
متن کاملThree-dimensional cholangiography applying C-arm computed tomography in bile duct carcinoma: a new radiological technique.
A C-arm equipped with a flat detector CT (C-arm CT) has been developed, which provides images with high spatial resolution that could facilitate effective 3D information during interventional procedures. The cone beam reconstructive method was applied for reconstruction of images. Time of reconstruction of 3D images was approximately one minute after the scan. The axial thin-slice images, the r...
متن کاملSystem to Guide Transcatheter Aortic Valve Implantations Based on Interventional C-Arm CT Imaging
Transcatheter aortic valve implantation is an emerging technique to be applied in patients with aortic valve defects. Angiographic and fluoroscopic X-ray imaging with a C-arm system is crucial in these minimally invasive procedures. We describe a prototypical system based on the ability to acquire a 3D C-arm CT image during transcatheter aortic valve implantations. It supports the physician in ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: World Journal of Cardiology
سال: 2016
ISSN: 1949-8462
DOI: 10.4330/wjc.v8.i10.606