Optimal Allocation of Inverter-Based WTGS Complying With Their DSTATCOM Functionality and PEV Requirements
نویسندگان
چکیده
منابع مشابه
Three-level NPC inverter based new DSTATCOM topologies and their performance evaluation for load compensation
Now-a-days for effective load compensation, a conventional three-level neutral point clamped (CNPC) inverter topology is more preferably used. This compensator, however, faces the problems of additional clamping diodes, which reduces the redundant switching states and improves the problem of capacitor voltage imbalance; further increasing the inverter cost. In this paper, a detailed analysis of...
متن کاملPerformance Analysis of Cascaded Multilevel Inverter Based DSTATCOM
In this paper, a single-phase Seven-Level and Five-Level cascaded H-Bridge Inverter (CHB) based Distribution Static Compensator (DSTATCOM) is presented. A simple control algorithm based on inverse park PLL was proposed for both five-level and seven-level inverters. Synchronous Reference Frame theory (SRF) as control algorithm is used for reference source current extraction and to generate gatin...
متن کاملOptimal PMU Placement Considering with HVDC Links and Their Voltage Stability Requirements
In wide area measurement systems, PMUs are the main component measuring real time synchronized data from different buses. Installation of PMUs at all buses is a primary way to provide full observability of the power network. However, it is not practical in real networks due to the relatively expensive cost of PMUs and other technical limitations. Optimal PMU Placement (OPP) is an optimization p...
متن کاملdetection of volatile compounds of medicinal plants with some nano-sorbents using modified or new methodologies and investigation of antioxidant activity of their methanolic extracts
in this work, a novel and fast method for direct analysis of volatile compounds (davc) of medicinal plants has been developed by holding a filament from different parts of a plant in the gc injection port. the extraction and analysis of volatile components of a small amount of plant were carried out in one-step without any sample preparation. after optimization of temperature, extraction time a...
Sliding Mode Control of DSTATCOM Using Seven Level Multilevel Inverter
In distribution system (DS), the majority of power consumption has been drawn in reactive loads. These loads are drawn in low power factor and therefore give rise to reactive power burden in the distribution system. So that DSTATCOM controller is used to compensate reactive power, correction of power factor and elimination of current harmonics. This paper presence the 7-Level Cascaded Hbridge I...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Vehicular Technology
سال: 2020
ISSN: 0018-9545,1939-9359
DOI: 10.1109/tvt.2020.2980971