Optical tweezer system with no fluorescent confocal microscope for trapping colloidal nanoparticles
نویسندگان
چکیده
منابع مشابه
Colloidal transport through optical tweezer arrays.
Viscously damped particles driven past an evenly spaced array of potential energy wells or barriers may become kinetically locked in to the array, or else may escape from the array. The transition between locked-in and free-running states has been predicted to depend sensitively on the ratio between the particles' size and the separation between wells. This prediction is confirmed by measuremen...
متن کاملOptical trapping of nanoparticles.
Optical trapping is a technique for immobilizing and manipulating small objects in a gentle way using light, and it has been widely applied in trapping and manipulating small biological particles. Ashkin and co-workers first demonstrated optical tweezers using a single focused beam. The single beam trap can be described accurately using the perturbative gradient force formulation in the case of...
متن کاملControlled Optical Trapping of Nanoparticles
In this paper, we present a summary of the main properties and difficulties when performing the characterization, the measurement, the identification and the control of systems dedicated to the micro/nano-world.
متن کاملTowards Optical Biopsies with an Integrated Fibered Confocal Fluorescence Microscope
This paper presents an integrated endoscope-compatible Fibered Confocal Fluorescence Microscope (FCFM) for medical imaging, the F400. In situ high resolution images can be obtained thanks to a set of flexible miniaturized optical probes of 0.5 to 1.5 mm diameter that can be inserted through the working channel of an endoscope. We briefly present in this paper the FCFM system, with a particular ...
متن کاملSpatial Intensity Correction of Fluorescent Confocal Laser Scanning Microscope Images
This paper addresses the problem of intensity correction of fluorescent confocal laser scanning microscope (CLSM) images. CLSM images are frequently used in medical domain for obtaining 3D information about specimen structures by imaging a set of 2D cross sections and performing 3D volume reconstruction afterwards. However, the images of optical sections acquired from fluorescent CLSM demonstra...