Optical quality after posterior chamber Phakic implantation of an intraocular Lens with a central hole (V4c implantable Collamer Lens) under different lighting conditions
نویسندگان
چکیده
منابع مشابه
Comparison of early changes in and factors affecting vault following posterior chamber phakic Implantable Collamer Lens implantation without and with a central hole (ICL V4 and ICL V4c)
BACKGROUND To objectively compare the early changes in vault over time following implantation of an Implantable Collamer Lens without (ICL V4) and with (ICL V4c) a central hole and the respective factors affecting vault change in moderate to high myopia. METHODS This prospective study comprised of 38 eyes of 38 patients implanted with ICL V4 and 39 eyes of 39 patients implanted with ICL V4c i...
متن کاملImplantable Collamer Lens Versus Iris-Fixed Phakic Intraocular Lens Implantation to Correct Myopia: A Meta-Analysis
This study is a meta-analysis comparing the efficacy, predictability, and safety of correcting myopia via implantation of two types of phakic intraocular lens (PIOLs): the implantable collamer lens (ICL) and iris-fixed PIOL. The Cochrane library, Pubmed, and EMBASE were searched. Study selection, data exclusion, and quality assessment were performed by two independent observers. The pooled rela...
متن کاملPosterior chamber phakic intraocular lens implantation for high myopia.
OBJECTIVE To evaluate the efficacy, safety and stability of posterior chamber phakic intraocular lens (PIOLs) implantation for the correction of high myopia. METHODS Thirty-nine eyes of twenty patients with high myopia (between -11.75 and -25.75 diopters) had a posterior chamber PIOL (Staar ICL) implanted. During 6 - 48 months' follow-up, visual acuity, refraction, intraocular pressure (IOP),...
متن کاملPosterior chamber collagen copolymer phakic intraocular lens with a central hole for moderate-to-high myopia
The purpose of this article is to evaluate the clinical outcomes of a posterior chamber phakic intraocular lens (pIOL) (Visian Implantable Collamer Lens V4c) for the correction of moderate to high myopia in Chinese eyes.The article is designed as a retrospective case series.This study included the first consecutive eyes that had implantation of a new pIOL design with a central hole, at our depa...
متن کاملPosterior Vitreous Detachment and Retinal Detachment After Implantation of the Visian Phakic Implantable Collamer Lens
INTRODUCTION To evaluate the vitreoretinal complications in myopes after Visian implantable collamer lenses (ICL) implantation. MATERIALS AND METHODS This is a retrospective, observational, non-comparative clinical study that evaluated 617 consecutive myopes who underwent ICL implantation at the Department of Refractive Surgery, Yemen Magrabi Hospital, Sana'a, Yemen between July 2006 and May ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: BMC Ophthalmology
سال: 2020
ISSN: 1471-2415
DOI: 10.1186/s12886-020-01340-0