Optical Heterodyne Vibrometer Utilizing the Inter-Mode Beat of a Two-Mode Stabilized He-Ne Laser.
نویسندگان
چکیده
منابع مشابه
Optical Frequency Metrology of an Iodine-Stabilized He-Ne Laser Using the Frequency Comb of a Quantum-Interference-Stabilized Mode-Locked Laser
We perform optical frequency metrology of an iodine-stabilized He-Ne laser using a mode-locked Ti:sapphire laser frequency comb that is stabilized using quantum interference of photocurrents in a semiconductor. Using this technique, we demonstrate carrier-envelope offset frequency fluctuations of less than 5 mHz using a 1 s gate time. With the resulting stable frequency comb, we measure the opt...
متن کاملA phase quadrature feedback interferometer using a two- mode He-Ne laser
A new feedback interferometer is developed with which not only the magnitude but also the sign of a phase change caused by a variation in the optical path can be measured. This is an important feature, for example, in plasma diagnostics. a He-Ke laser. The two interference signals can be separately detected by virtue of the orthogonal polarisation of the two axial modes of the laser without Bre...
متن کاملLaser vibrometer based on optical-feedback-induced frequency modulation of a single-mode laser diode.
We describe a sensitive and inexpensive vibrometer based on optical feedback by diffuse scattering to a single-mode diode laser. Fluctuations in the diode laser's operating frequency that are due to scattered light from a vibrating surface are used to detect the amplitude and frequency of surface vibrations. An additional physical vibration of the laser provides an absolute amplitude calibratio...
متن کاملTwo-mode heterodyne phase detection.
We present an experimental scheme that achieves ideal phase detection on a two-mode field. The two modes a and b are the signal and image band modes of an heterodyne detector, with the field approaching an eigenstate of the photocurrent Ẑ = a + b†. The field is obtained by means of a high-gain phase-insensitive amplifier followed by a high-transmissivity beam-splitter with a strong local oscill...
متن کاملError Analysis, Design and Modeling of an Improved Heterodyne Nano-Displacement Interferometer
A new heterodyne nano-displacement with error reduction is presented. The main errors affecting the displacement accuracy of the nano-displacement measurement system including intermodulation distortion error, cross-talk error, cross-polarization error and phase detection error are calculated. In the designed system, a He-Ne laser having three-longitudinal-mode is considered as the stabiliz...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The Review of Laser Engineering
سال: 1995
ISSN: 0387-0200,1349-6603
DOI: 10.2184/lsj.23.1124