Optical-Fiber-Based Smart Concrete Thermal Integrity Profiling: An Example of Concrete Shaft
نویسندگان
چکیده
منابع مشابه
Green Specifications: A Concrete Example
Green specifications provide a foundation for reducing the environmental impact of computing applications and improving the consumption behavior of users by providing a clear and precise specification of the environmental impact of specific services. They can either be used to specify the actual behavior and environmental impact of existing services or to define the requirements that a to-be-bu...
متن کاملCracking Assessment in Concrete Structures by Distributed Optical Fiber
In this paper, a method to obtain crack initiation, location and width in concrete structures subjected to bending and instrumented with an OBR system (Optical Backscattered Reflectometer) is proposed. Continuous strain data with high spatial resolution and accuracy are the main advantages of the OBR system. These characteristics make this Structural Health Monitoring (SHM) technique a useful t...
متن کاملStatistics of Parameter Estimates: A Concrete Example
Most mathematical models include parameters that need to be determined from measurements. The estimated values of these parameters and their uncertainties depend on assumptions made about noise levels, models, or prior knowledge. But what can we say about the validity of such estimates, and the influence of these assumptions? This paper is concerned with methods to address these questions, and ...
متن کاملMarket Structure and Productivity: A Concrete Example
This paper shows that imperfect output substitutability explains part of the observed persistent plant-level productivity dispersion. Specifically, as substitutability in a market increases, the market’s productivity distribution exhibits falling dispersion and higher central tendency. The proposed mechanism behind this result is truncation of the distribution from below as increased substituta...
متن کاملCarbon Fiber Post-Strengthening of Concrete Structures
Introduction In the 1970s, exterior bonded steel reinforcement was used sporadically to reinforce bridges to attain higher service load capacities. This steel post-strengthening system consisted of steel straps bonded with epoxies to the exterior of concrete beams. An alternative to the steel retrofit is woven carbon fiber reinforced polymer fabric applied in the same manner as steel. Carbon fi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Advances in Materials Science and Engineering
سال: 2018
ISSN: 1687-8434,1687-8442
DOI: 10.1155/2018/9290306