Optical-fiber-based Mueller optical coherence tomography

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comment on "Optical-fiber-based Mueller optical coherence tomography".

We comment on the recent Letter by Jiao et al. [Opt. Lett. 28, 1206 (2003)] in which a polarization-sensitive optical coherence tomography system was presented. Interrogating a sample with two orthogonal incident polarization states cannot always recover birefringence correctly. A previously presented fiber-based polarization-sensitive system was inaccurately characterized, and its method of el...

متن کامل

Fiber-optic-bundle-based optical coherence tomography.

A fiber-optic-bundle-based optical coherence tomography (OCT) probe method is presented. The experimental results demonstrate this multimode optical fiber-bundle-based OCT system can achieve a lateral resolution of 12 microm and an axial resolution of 10 microm with a superluminescent diode source. This novel OCT imaging approach eliminates any moving parts in the probe and has a primary advant...

متن کامل

Reply to Comment on “Optical-fiber-based Mueller opticalcoherence tomography”

We do not agree with any of the comments made by Park et al. about our Optics Letters paper. The following replies appear in the order of their remarks. In a previous publication we analyzed in detail the limitation of using orthogonal incident polarization states for the determination of some special Jones matrices and indicated a solution based on nonorthogonal incident polarization states. W...

متن کامل

Fiber-based polarization-sensitive Mueller matrix optical coherence tomography with continuous source polarization modulation.

We report on a new configuration of fiber-based polarization-sensitive Mueller matrix optical coherence tomography that permits the acquisition of the round-trip Jones matrix of a biological sample using only one light source and a single depth scan. In this new configuration, a polarization modulator is used in the source arm to continuously modulate the incident polarization state for both th...

متن کامل

In vivo burn imaging using Mueller optical coherence tomography.

We report on the use of a high-speed, fiber-based Mueller-matrix optical coherence tomography system with continuous source-polarization modulation for in vivo burn depth evaluation and healing monitoring. A homemade hand-held probe with integrated optical scanning and beam delivering optics was coupled in the sample arm. In vivo burn imaging was demonstrated on porcine skin at different stages...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Optics Letters

سال: 2003

ISSN: 0146-9592,1539-4794

DOI: 10.1364/ol.28.001206