Optical-CT 3D Dosimetry Using Fresnel Lenses with Minimal Refractive-Index Matching Fluid

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optical-CT 3D Dosimetry Using Fresnel Lenses with Minimal Refractive-Index Matching Fluid

Telecentric optical computed tomography (optical-CT) is a state-of-the-art method for visualizing and quantifying 3-dimensional dose distributions in radiochromic dosimeters. In this work a prototype telecentric system (DFOS-Duke Fresnel Optical-CT Scanner) is evaluated which incorporates two substantial design changes: the use of Fresnel lenses (reducing lens costs from $10-30K t0 $1-3K) and t...

متن کامل

Optical Design using Fresnel Lenses

The Fresnel lens can be used in a wide variety of applications. The basic principles of the Fresnel lens are review­ ed and some practical examples are des­ cribed. There are definite advantages and tradeoffs that should be considered when deciding if a Fresnel lens is the appropri­ ate component to use in a design. Some basic optimization rules are presented which may facilitate a first order ...

متن کامل

Eliminating the need for refractive index matching in optical CT scanners for radiotherapy dosimetry: I. Concept and simulations.

Optical computed tomography has now become a well-established method for making empirical measurements of 3D dose distributions in radiotherapy treatment verification. The requirement for effective refractive index matching as part of the scanning process has long been an inconvenience for users, limiting the speed of sample throughput. We propose a new method for reconstructing data that takes...

متن کامل

3D dosimetry by optical-CT scanning.

The need for an accurate, practical, low-cost 3D dosimetry system is becoming ever more critical as modern dose delivery techniques increase in complexity and sophistication. A recent report from the Radiological Physics Center (RPC) (1), revealed that 38% of institutions failed the head-and-neck IMRT phantom credentialing test at the first attempt. This was despite generous passing criteria (w...

متن کامل

Investigations into the feasibility of optical-CT 3D dosimetry with minimal use of refractively matched fluids.

PURPOSE In optical-CT, the use of a refractively matched polyurethane solid-tank in place of a fluid bath has the potential to greatly increase practical convenience, reduce cost, and possibly improve the efficacy of flood corrections. This work investigates the feasibility of solid-tank optical-CT imaging for 3D dosimetry through computer simulation. METHODS A matlab ray-tracing simulation p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: PLOS ONE

سال: 2016

ISSN: 1932-6203

DOI: 10.1371/journal.pone.0152606